Re: RACF server disabled During IPL

2011-09-23 Thread Franz Josef Pohlen
restore your RACF db. We had pinned data on a DS8000 after unplanned loss of power which is in result the same as your ESS error. IBM 2nd level support had to reset the cache data. After that we could start the system again. kind regards Franz Josef Pohlen Am 23.09.2011 09:55, schrieb jagadishan

Re: how is the machine capacity resetted to normal state after activation of cbu record

2010-06-16 Thread Franz Josef Pohlen
will do the deactivation manually after the test. Regards Franz Josef Pohlen Original-Nachricht Datum: Wed, 16 Jun 2010 01:09:06 -0500 Von: Marc Wambeke marc.wamb...@realdolmen.com An: IBM-MAIN@bama.ua.edu Betreff: Re: how is the machine capacity resetted to normal state

how is the machine capacity resetted to normal state after activation of cbu record

2010-06-15 Thread Franz Josef Pohlen
to a a01. Will it be done automatically or must it be done again with perform model conversion? Does anybody have experiences with this scenario and can give me any hints how the capacity is reset after the test? Thanks in advance Franz Josef Pohlen -- GRATIS für alle GMX-Mitglieder: Die maxdome

Re: RRS start order

2006-09-04 Thread Franz Josef Pohlen
I start always RRS first. Franz Josef Original-Nachricht Datum: Mon, 4 Sep 2006 15:55:27 +0200 Von: R.S. [EMAIL PROTECTED] An: IBM-MAIN@BAMA.UA.EDU Betreff: [IBM-MAIN] RRS start order What should I start first during IPL: RRS started task or rather Resource Managers (DB2,