Is it possible to move all of the datasets that are shipped with a z/os
serverpac from SMS managed pacs to a single mod 27 using adrsdssu? Will
all of the datasets move, (Haspace, Page datasets, logrecs.etc)?
Thanks.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This
I used the example on the IBM website to get the maintenance for z/OS
V1R8. I am getting the following message:
Connecting to: dispsd-76.boulder.ibm.com 207.25.253.76 port: 21.
Connection to server interrupted or timed out. Initial connection
Std Return Code = 1, Error Code = 8
Is th
Does the SMPNTS directory have to be a ZFS file, and how much space
should be allocated to it for use in RECEIVE FROMNETWORK process of an
entire z/os Release. Thanks.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may contain confid
Thanks to all who responded. Have a workable solution.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may contain confidential,
proprietary or non-public information. This information is intended
solely for the designated recipient(s)
I removed CSF.SCSFMOD0 from the LNKLST and the APF list, but when I
attempt to delete I get an error message saying it is in use. It appears
there it is used by LLA and XCFAS. How can I realese the Dataset from LLA
and XCFAS? Thanks.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PRO
We are attempting to run full volume dumps prior to moving from one system
to another. We use ARCCMD to set the DUMP for Saturday and Sunday. We
want to run them on Friday night. We modified the ARCCMD and then cycle
HSM. However when we go to use the tapes on Friday night, HSM will not
let
Does anyone have the email address for the "Ask Sam Palmisano" or IBM CEO
Sam Palmisano.
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Searc
During SMP/E mantenance a system fils CSF.SCSFMOD0 had a d37. I removed
the file from the PLEX and wanted to increase it's size. It appears the
LLA and XCFAS on the on the other LPAR's in the system have enque on the
name. How can I remove the enqueue so I can increase and copy the file.
Than
I am cloning a target region for maintenance. I would like to find a
utility that will insert a VOLSER in the VOLUME parameter on the DDDEF.
Currently none of the DDDEF's have volsser numbers in them. The ZONEDIT
CHANGE command will not let me do a global change on VOLUME when the
VOLUME is
Is ther a command that can be entered from TSO/ISPF to find out what
version of TCP/IP that is being run in an LPAR on a z/900 (z/OS 1.7)
Thanks.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may contain confidential,
proprietary or n
Does anyone have any experience with Oracle Identity Manager Connector for
RACF Advanced? Our Security Dept. is going to deploy the product in our
company and it looks like there are a lot of issues with it running on a
z9. Any feedback would be appreciated.
Mark House
(402) 778-1966
IBM Main
Can we put the z/OS R1.8 System on one 3390-27. Is there any IBM
Documentation giving limitations or recommendations.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may contain confidential,
proprietary or non-public information. This
No Text
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may contain confidential,
proprietary or non-public information. This information is intended
solely for the designated recipient(s). If an addressing or transmission
error has m
We are upgrading from a 2064 to a 2096. Our 2064 SYSPLEX contains one
LPAR running z/OS 1.4. Is anyone running z/OS 1.4 on a 2096? If so, any
problems or suggestions? Thanks.
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may conta
Looking for recommendations on adding an 80 megabyte load module to the
LPA. What are the negatives. The reason we would like to do this is that
one of our application programs that use this module can be used by 1 to
10 jobs running at the same time. Our thought is that by making this
modul
Mark House
(402) 778-1966
IBM Mainframe Systems
[EMAIL PROTECTED]
This e-mail message and any attachments may contain confidential,
proprietary or non-public information. This information is intended
solely for the designated recipient(s). If an addressing or transmission
error has misdirecte
Summary: When IPL, datasets that are in SYS1.PARMLIB(PROGP1)that are
defined with LNKLST ADD statements are not added to the LNKLST UNLESS they
are on a SYSRES pack or in the master catalog.
I do not want to VOLSER the DSN as they may be moved from only volume to
another. This would cause us
17 matches