Re: Problem with a CVC defined channel

2007-11-16 Thread Paolo Pirillo
Hello Walter, Because there is only this device attached on this channel and only the PROD LPAR needs access. On the previous channel there are attached 4 devices like printers etc. I defined the new statement with HCD. What you see is the extract from HCD. I defined the new channel dedicated, so

Re: Problem with a CVC defined channel

2007-11-16 Thread Walter Marguccio
- Original Message From: Paolo Pirillo [EMAIL PROTECTED] old: PARTITION=((PRODUKT),(ENTWICK,SYSPROG),REC),PCHID=160, * === new: PARTITION=((PRODUKT),(=)),PCHID=16C, * === Paolo, why did you change the PARTITION statement ? In the second stmt looks like PRODUKT is

Problem with a CVC defined channel

2007-11-15 Thread Paolo Pirillo
Hello to all. I have a Problem with a Device on a CVC CHP. I defined for that Device a new CHP so this device will the only one on this CHP. On the old CHP it goes online an works. After changing to the new CHP (only switching the ESCON cable to the new 9034 it comes out with a HW failure. I