Just curious

2012-01-26 Thread Carlos Bodra - Pessoal
Just out of curiosity, what was the code name of the IBM z114. FREEWAY was z900, z10 BC and was GRYPHON so on. -- Carlos Bodra São Paulo - SP Brazil -- For IBM-MAIN subscribe / signoff / archive access instructions, send email

Re: Android 3270 emulators

2012-01-18 Thread Carlos Bodra - Pessoal
Well a lot of them, but any one specific for Android and free? I can´t find it. Em 18/01/2012 18:48, George, William@FTB escreveu: Duh!! LOL! Never crossed my mind to google it. Sheesh. Thanks -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@bama.ua.edu] On

Re: ACCOUNT Product

2012-01-11 Thread Carlos Bodra - Pessoal
There are some good products available in many vendors (CA, BMC, etc...) that expand control over account. Keep in mind that 10% of use o CPU, consume DASD access and some gigabytes stored in you storage subsystem. This access to DASD means too IP or SNA traffic. This envolves gateways,

ADRDSSU Compatibility

2011-11-18 Thread Carlos Bodra - Pessoal
If I have a volume backed up using ADRDSSU 1.11 (DUMP DATASET) is possible to restore it using ADRDSSU 1.10? (backward compatibility) -- Carlos Bodra São Paulo - SP Brazil -- For IBM-MAIN subscribe / signoff / archive access

IPL abend z/os 1.8

2011-09-20 Thread Carlos Bodra - Pessoal
We are trying to IPL an z/OS 1.8 to update it to support a z10 machine. Today it is running over an z890. During IPL we got following abend: 18.45.46 *IEE479W MASTER SCHEDULER ABEND 052, REIPL - CODE 14 18.45.46 IEA794I SVC DUMP HAS CAPTURED: DUMPID=001 REQUESTED BY JOB

DS6800 and OS/390 2.9

2011-09-13 Thread Carlos Bodra - Pessoal
Hello List Gurus. We are in process of migrate from an ancient IBM 2105-F20 with 1TB of legacy mainframe data to a IBM 1750-522 (DS6800). Both subsystems has volumes defined as 3390-3 and no software features (flashcopy, pprc etc..) used in Shark and will neither in DS6800. My question is,

CSA and SQA problem

2011-08-25 Thread Carlos Bodra - Pessoal
Hello We have an z/os 1.8 running under a lpar in a z890. Now we have a chance to move it to a z10 BC machine, but during IPL we are getting iea304w wait 80009064. We already tried a lot of combinations of CSA, ECSA, SQA and ESQA values and we continue to getting waits during IPL. Since z/OS

Re: TS1120 Drives: will they support 10/20 GB J tapes ?

2011-08-18 Thread Carlos Bodra - Pessoal
3590 J tapes are physically different. As 3490 cartridges can´t be used in 3590, same for 3590 cartridges can´t be loaded in ts1120 drives... Carlos Bodra IBM Certified Specialist System z Sao Paulo - Brazil Em 18/08/2011 18:04, Clark, Kevin escreveu: Hello all, Let me answer the

Re: How to get Operator Log

2011-08-03 Thread Carlos Bodra - Pessoal
Goes to Operator cms machine, and give cp sp cons clo Thsi should close console log from IPL until now and generate a Printer file. You can trans fer this printer file from Operator to your cms machine and using RDRList watch it to check what happens. Carlos Bodra IBM Certified

Re: How to get Operator Log

2011-08-03 Thread Carlos Bodra - Pessoal
trans operator prt xxx to yourmachine r xxx = spool file id Give this command on operator machine Carlos Bodra IBM Certified Specialist System z Sao Paulo - Brazil Em 03/08/2011 14:47, saurabh khandelwal escreveu: Thanks for reply. I used cp sp cons clo command to lose console

Re: How to get Operator Log

2011-08-03 Thread Carlos Bodra - Pessoal
NO FILES TRANSFERRED 19:24:31 HCPCSC042E User OPERATOR spoolid 0002 does not exist Ready(00042); T=0.01/0.01 19:24:31 Can you please help me, how do I check spool file id. Regards Saurabh On Wed, Aug 3, 2011 at 11:21 PM, Carlos Bodra - Pessoal cbo...@terra.com.br wrote: trans operator

Re: HMC definition for z/VM IFLs on a z196

2011-07-26 Thread Carlos Bodra - Pessoal
Yes z/VM can bring up with a IFL only partition. If you choose z/VM mode you can select IFL and is mandatory to select a CP too. This is useful when you want to run z/VSE under z/VM and some Linux on Z machines under same z/VM. z/VSE nor z/OS will run under a z/VM with IFL only engines.

Re: z196-BC announcement pending?

2011-07-01 Thread Carlos Bodra - Pessoal
It´s a z196 BC announcement.! Carlos Bodra IBM Certified Specialist System z Sao Paulo - Brazil Em 30/06/2011 16:33, Pommier, Rex R. escreveu: Just got an invite to a live virtual event on July 12 regarding the evolution of the z hybrid. Here is the first paragraph of the

TCPIP PROFILE

2011-07-01 Thread Carlos Bodra - Pessoal
Hello TCP/IP z/OS gurus I need to configure a telnet access thru tcpip z/OS 1.5. Since I´m not familiar to this, seems that all is defined in gateway statement. My home address will 192.168.1.230, gateway is 192.168.1.225 and network mask is 255.255.255.240 How should I define my gateway

z/OS 1.4 Compatibility feature for z890.

2011-06-15 Thread Carlos Bodra - Pessoal
Hello, What is this feature? It´s a non priced feature, but it´s available in all z/OS 1.4 by applying ptf´s or is a separeted cartrigde to be use during installation of z/OS 1.4? If I have a z/OS 1.4 and wants to run it over z890, I will need Compatibility feature only if z890 is part of

IBM Announcements Today

2011-04-12 Thread Carlos Bodra - Pessoal

Re: Check TAPE Contents

2011-03-23 Thread Carlos Bodra - Pessoal
Sergio, Check security programs (Racf/TopSecret/Acf-2 etc..) Bellow is Installation and Customization Manual http://www-05.ibm.com/e-business/linkweb/publications/servlet/pbi.wss?CTY=USFNC=SRXPBL=GC26-9598-00 Have fun!!! Carlos Bodra IBM zSeries Certified Specialist Sao Paulo -

PSP for z/os.e 1.8

2010-12-17 Thread Carlos Bodra - Pessoal
Hi listners, I´m new to z/os world, and need some clarification about following subject. We are moving from z890 to a brand new z10 BC. Our current z/os.e version is 1.8 (last). Before I can ipl this version under z10 control, I need to apply z/os.e Preventive Service Planning mainly to get

z/os x z/os.e differences

2010-12-17 Thread Carlos Bodra - Pessoal
Hi listners, Contuning my saga about z/os.e and z10 BC, we tried to IPL it before install psp and get following message: IFA200W LICENSE=z/OSe WAS SPECIFIED BUT IS NOT ALLOWED. This message says that z/os.e runs only in z800 and z890 machines and Lpars needs to have an specific name

Re: Z10 BC SNA Console

2010-11-30 Thread Carlos Bodra - Pessoal
Hello, Iff you have OSA-E 1000BaseT look for in redbook site for OSA-ICC. It describes step by step how to configure it. Carlos Bodra IBM zSeries Certified Specialist Sao Paulo - Brazil Em 30/11/2010 15:42, SrinivasG escreveu: Hi, On the Z800 , we had a separate 2074

zOSe and z10 - Urgent

2010-11-25 Thread Carlos Bodra - Pessoal
Hello, Can I run, zOSe 1.6 under a z10 machine? This is for a temporary migration, since customer has a z890 today and z10 announcement didn´t show zOSe as a supported system. Any real experiences? Thanks -- Carlos Bodra IBM zSeries Certified Specialist Sao Paulo - Brazil

EREP dump readout for MCIC

2010-10-14 Thread Carlos Bodra - Pessoal
Hi listners. I was checking erep output to try to discover more about MCIC (Machine Check Interruption Code) and found following register, but I checked 02 Erep manuals, (User´s Guide Manual and Reference Manual), but can´t found any description how to readout these little dump. We are

ESS800 Configuration

2010-10-05 Thread Carlos Bodra - Pessoal
Hi We are in process to configure some area of our 2105-800 to be used by open systems. We start process and when we try to building host access (option modify host), we got in ESS Specialist console following message: ERROR 1199 Information server problem. An unknown server error occurred.

Code names for zSeries

2010-09-03 Thread Carlos Bodra - Pessoal
Warning: This email was cross posted to IBM-MAIN, IBMVM and VSE-L Lists. As z196 has a code name of *Gryphon* before announcement, other zSeries has similar names, as *T-Rex* (z990??) *Pterodactylus*/ (z890???) Anyone has all family names? z900 - z800 - z990 - /*T-Rex*/ z890 -

Re: Oracle: The future is diskless!

2010-08-12 Thread Carlos Bodra - Pessoal
Last mainframe will turned off in 1996 hahahahaha No more than 640KB is necessary for any computer hahahahaha These new predictions make same effect. Carlos Bodra IBM zSeries Certified Specialist Sao Paulo - Brazil Em 11/08/2010 15:42, Mark Pace escreveu: Bubbles!!

Re: Oracle: The future is diskless!

2010-08-12 Thread Carlos Bodra - Pessoal
Hi Rick, You just forgot to say that 100,000 acres are under water in middle of great lakes... but I will consider this offer when I decide to invest in real estate!!! Carlos Bodra IBM zSeries Certified Specialist Sao Paulo - Brazil Em 12/08/2010 18:53, Scott Rowe escreveu: