Hi
I just got abend while doing a DETACH normally I look at offset hex +18
SDWAGRSV for the program registers this time however the registers belonged
to IGC062 and mine was at SDWA offset hex +88
I was running under TESTAUTH so I was able to recognize it my question is
programmatically
0388 is a class-3 error (invalid parameter list), assigned by DAIR, meaning "A
required key not specified for any of the following requests":
ddname allocation,
information retrieval,
concatenation,
deconcatenation,
remove In - Use,
unallocation.
On Mon, 29 Oct 2018 16:02:30 -0400, Steve
Yeah. But it also says go read the text units to see what else they require.
The DDNAME unit doesn’t require anything else. So I’m baffled as to why it says
this and there are no “extra” requirements given.
Sent from my iPhone — small keyboarf, fat fungrs, stupd spell manglr. Expct
mistaks
The TSO message and DAIR return code 388 indicate a missing or invalid
parameter to DAIRFAIL.
https://www.ibm.com/support/knowledgecenter/SSLTBW_2.1.0/com.ibm.zos.v2r1.ikjb700/ikjb700_The_Parameter_List.htm
In a message dated 10/29/2018 3:03:16 PM Central Standard Time,
ste...@copper.net
I'm testing a special in-house developed utility. So it is
designed to be invoked by a COBOL program.
I'm going to tell you how I got here and all the stuff I've been
doing, and then the effects of the SIS (IBMLink search), etc.
before I ask my question.
So a test of the code, once fixed to
Hi Jim,
Thank you for the very helpful answer.
I got sidetracked with work and travel, and did not get back here for a little
while.
I do appreciate your response.
--
For IBM-MAIN subscribe / signoff / archive access
W dniu 2018-10-29 o 17:31, IBM user pisze:
1. IBM states that in a Crypto Express card is highly recommended in a
production environment.
We are investigating DSN encryption for a handful of datasets, for data-at-rest
encryption.
My understanding is that without the card, the CKDS key dataset
1. IBM states that in a Crypto Express card is highly recommended in a
production environment.
We are investigating DSN encryption for a handful of datasets, for data-at-rest
encryption.
My understanding is that without the card, the CKDS key dataset contains keys
in the clear, and that the
Example 12 in the INREC control statement section of the DFSORT Application
Programming Guide (SC26-7523-04) seems pretty close to what you want.
> -Original Message-
> From: IBM Mainframe Discussion List On
> Behalf Of Gil Cardenas
> Sent: Monday, October 29, 2018 5:06 AM
> To:
Thanks for the advice on Sizer utility. In our present case, however, new and
old CECs will not be connected at the same time. An installation decision made
some time ago. We are able to run our sandbox sysplex ahead of time on the new
CECs but without concurrent connection on the old CECs. So
I'm going to attach HMC remotely.
Remote means it is behind the router, so no broadcasts are realayed,
that alos mean one has to provide IP of the CPC (instead of
auto-detection), etc.
However due to some limitations I need to use NAT (Network Address
Translation) - is it acceptable for HMC? I
Hi Tom,
Yes, I have quite a few STORAGE Volumes with the correct amount of space.
It's also true that these UCBs are not contained within the Esoteric
definition of SYSDA.
I am trying to figure out where the ALLOCATion of Logstream Datasets is
getting its UNIT value.
Regards,
David
On
On Sun, 28 Oct 2018 23:34:53 +, David Spiegel Hi,
>I am trying ALLOCATE (z/OS 2.3) non-SMS Managed RRS Logstream Datasets.
>This used to work, before I changed the Mount Attribute of the
>zPDT-supplied Volumes (A3*) from STORAGE to PRIVATE.
Why did you do that? Do you have any STORAGE
Please explain the difference? :-)
On Sun, Oct 28, 2018 at 7:00 PM Matt Hogstrom wrote:
> RedHat isn’t in the open source business. They are in the corporate
> software business based on open source.
>
> Matt Hogstrom
> m...@hogstrom.org
> +1-919-656-0564
> PGP Key: 0x90ECB270
> Facebook
Well thank y'all. I guess that's about what I expected.
On Sun, Oct 28, 2018 at 1:53 PM Binyamin Dissen
wrote:
> On Sun, 28 Oct 2018 08:12:49 -0700 Beverly Caldwell >
> wrote:
>
> :>Does anyone know, by any chance, if there is any (legitimate) way to rid
> :>oneself of an unwanted STEPLIB
You also need to modify /etc/rc
-Original Message-
From: IBM Mainframe Discussion List On Behalf Of
Giliad Wilf
Sent: Sunday, October 28, 2018 4:40 AM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: We're IST-2IDT, and switching back from UTC+3 to UTC+2 at 2AM Oct.
28th
Yes,
I did set TZ
As Peter points out, the Sizer utility, rather than CFSizer, is the tool of
choice for resizing structures in anticipation of a CFLEVEL change. CFSizer
(https://www-01.ibm.com/support/docview.wss?uid=isg3T1027062) is appropriate
when you're introducing a new workload or changing a workload for
Sorry for the long winded explanation but need to set the context of the issue.
Background:
I have a print file (LRECL=133, RECFM=FBA) that I am working with that contains
report data and is a rather large file 2,000 cylinders.
I need to extract some statistics from the file but the format
I've seen /r/sysadmin on Reddit lose their collective mind about the news
regarding Big Blue's purchase of RedHat. It appears to me that IBM has been
putting a lot of investment in open source for the past few years...especially
within the z/OS ecosystem. They may be doing it to get deeper
19 matches