Larger number in fewer bytes.
-Original Message-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of John McKown
Sent: Wednesday, May 04, 2016 1:17 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: Re: ADR309E Message during Restore
On Wed, May 4, 2016 at 1:01 PM
Thanks very much for this. Really I don´t guess about to read 2721 as
hexa number but a normal number since it isn´t in x'' or 0x.
0d0b is clear that is hexa number but 2721 isn´t. Any way thanks again.
CARLOS BODRA
IBM Certified zSystem
São Paulo - SP - BRAZIL
Em 04/05/2016 15:16, Jo
On Wed, 4 May 2016 13:16:38 -0500, John McKown wrote:
>On Wed, May 4, 2016 at 1:01 PM, J R wrote:
>> In light of this confusion, one wonders why the developer opted to format
>> the message in hexadecimal.
>
>At the very least, he should have either done a x'' like HLASM or a
>0x like C.
On Wed, May 4, 2016 at 1:01 PM, J R wrote:
> In light of this confusion, one wonders why the developer opted to format
> the message in hexadecimal.
>
At the very least, he should have either done a x'' like HLASM or a
0x like C.
>
> Sent from my iPhone
>
> > On May 4, 2016, at 13:5
On 5/4/2016 10:41 AM, Carlos Bodra wrote:
SOURCE AND TARGET DEVICE CAPACITIES DO NOT MATCH. CYLINDER CAPACITY OF
SOURCE VOLUME 2721, TARGET VOLUME 0D0B.
This tells me that source volume has 2721 cylinders and target volume
has 3339 cylinders (0d0b).
No, the source volume has 10017 cylinders (x
In light of this confusion, one wonders why the developer opted to format the
message in hexadecimal.
Sent from my iPhone
> On May 4, 2016, at 13:56, Greg Dyck wrote:
>
>> On 5/4/2016 10:41 AM, Carlos Bodra wrote:
>> SOURCE AND TARGET DEVICE CAPACITIES DO NOT MATCH. CYLINDER CAPACITY OF
>> SO
-
From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Carlos Bodra
Sent: Wednesday, May 04, 2016 1:41 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: ADR309E Message during Restore
Hello
I´m trying to restore a full volume backed up with ADRDSSU utility and during
restore I
If this was a logical dump, you could restore the individual datasets. Execute
the restore job with PARM='TYPRUN=NORUN' to get a list of the individual
datasets.
If this is a physical dump, you have no choice. You *MUST* provide at least
a 3390-9 to restore successfully.
X'2721' is 10017 cy
Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf
Of Carlos Bodra
Sent: Wednesday, May 04, 2016 1:41 PM
To: IBM-MAIN@LISTSERV.UA.EDU
Subject: ADR309E Message during Restore
Hello
I´m trying to restore a full volume backed up with ADRDSSU utility and during
restore I´m getting
Hello
I´m trying to restore a full volume backed up with ADRDSSU utility and
during restore I´m getting following message:
SOURCE AND TARGET DEVICE CAPACITIES DO NOT MATCH. CYLINDER CAPACITY OF
SOURCE VOLUME 2721, TARGET VOLUME 0D0B.
This tells me that source volume has 2721 cylinders and t
10 matches
Mail list logo