Re: BLS18160D Response

2021-03-01 Thread Jim Mulder
ow dumping works. Jim Mulder z/OS Diagnosis, Design, Development, Test IBM Corp. Poughkeepsie NY "IBM Mainframe Discussion List" wrote on 02/27/2021 09:03:17 PM: > From: "Ed Jaffe" > To: IBM-MAIN@LISTSERV.UA.EDU > Date: 03/01/2021 05:04 PM > Subject: BL

Re: BLS18160D Response

2021-03-01 Thread Jim Mulder
. Jim Mulder z/OS Diagnosis, Design, Development, Test IBM Corp. Poughkeepsie NY "IBM Mainframe Discussion List" wrote on 02/28/2021 11:08:55 AM: > From: "Ed Jaffe" > To: IBM-MAIN@LISTSERV.UA.EDU > Date: 03/01/2021 04:09 PM > Subject: Re: BLS18160D Response >

Re: BLS18160D Response

2021-03-01 Thread Jim Mulder
instruction, those things are in agreement. Jim Mulder z/OS Diagnosis, Design, Development, Test IBM Corp. Poughkeepsie NY "IBM Mainframe Discussion List" wrote on 03/01/2021 04:26:52 AM: > From: "Barbara Nitz" > To: IBM-MAIN@LISTSERV.UA.EDU > Date: 03/01/2021 04:1

Re: BLS18160D Response

2021-03-01 Thread Matthew Stitt
An SDC2 abend on a JES2 warm start? Sounds very familiar. I spent quite a bit of time with support over that. Here is what was finally determined: OA58190 has changed the JES2 checkpoint structure, which is independent of user activity. Such internal changes are necessary in order to

Re: BLS18160D Response

2021-03-01 Thread Barbara Nitz
On Sun, 28 Feb 2021 08:08:55 -0800, Ed Jaffe wrote: >I don't experience issues displaying keys using DISPLAY(MACHINE) when >responding 'Y' to BLS18160D. Did you compare the keys with what rsmdata knows about the key of the page? I learned to use 'yes' to the BLS message and only to use the

Re: BLS18160D Response

2021-02-28 Thread Ed Jaffe
On 2/27/2021 7:48 PM, Mark Jacobs wrote: >From the FM; The summary dump data contains data captured closest to the time of the failure. If you reply Y to use this data, IPCS will not be able to display storage keys using the DISPLAY(MACHINE) parameter. Yeah, but... I don't experience

Re: BLS18160D Response

2021-02-27 Thread Mark Jacobs
>From the FM; The summary dump data contains data captured closest to the time of the failure. If you reply Y to use this data, IPCS will not be able to display storage keys using the DISPLAY(MACHINE) parameter. In some cases, the dump values generated when summary dump data is processed can

BLS18160D Response

2021-02-27 Thread Ed Jaffe
Regarding: "BLS18160D May summary dump data be used by dump access?  Enter Y to use, N to bypass." Under what conditions would it ever be appropriate to reply N? -- Phoenix Software International Edward E. Jaffe 831 Parkview Drive North El Segundo, CA 90245 https://www.phoenixsoftware.com/