Re: Using different PROCLIB concatenation in JES2 MAS

2012-09-13 Thread sachin kakkookal
Hi Munif , As Lizette said , using a JOBPARM card in the JCL to point to the right proclib concatenation is a good option which i can think of as it will be picked up first in the search order Regards , Sachin On 9/13/12, Lizette Koehler stars...@mindspring.com wrote: Munif, When you have

Re: Using different PROCLIB concatenation in JES2 MAS

2012-09-13 Thread Lizette Koehler
Munif, Since I do not know your site, this is just a suggestion. And you need to verify that it would work for your shop. In JES2 Deck you create 2 PROCLIB statements PROCLIB00 is for PRODUCTION and requires no JCL changes. So SYS1.PROCLIB and (for example) PROD.PROCLIB are defined there.

Re: Using different PROCLIB concatenation in JES2 MAS

2012-09-12 Thread Ed Gould
*IF* you can identify by jobname which JCLLIB order you should be able (not tried) to do it in on of the JES exits. Ed On Sep 12, 2012, at 10:10 PM, Munif Sadek wrote: Hello Listers Jobs are submitted using WLM initiators form Production and Development systems in our shared JES2 MAS.

Re: Using different PROCLIB concatenation in JES2 MAS

2012-09-12 Thread Doron Geva
Try $T JOBCLASS. It will let you automate the definition of the jobclass by time Another JES2 command that you may neen is $T PROCLIB to set the JES2 PROCLIB correctly Doron On Thu, Sep 13, 2012 at 6:37 AM, Ed Gould edgould1...@comcast.net wrote: *IF* you can identify by jobname which JCLLIB

Re: Using different PROCLIB concatenation in JES2 MAS

2012-09-12 Thread Lizette Koehler
Munif, When you have a shared JES MAS, the job can be converted on any LPAR. So there is no guarantee that a job submitted on LPAR1 will convert on LPAR1. So, the only option would be to use JCLLIBs and use Symbolics in the names. However, you could use an exit like IKJEFT10 for TSO or a