Re: Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-14 Thread Max Smith
If you still have the CDS's at the remote site you should be able to issue LIST DSN MCDS SEL(VOL(123456)) ODS(some.dsn) I would expect this to list all the current active data sets on the tape. Then at the main site you would want to catalog all these data sets. Then ADDVOL the migration

Re: Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-13 Thread Joel C. Ewing
So an inspection of the tape physical tape records would be one way to get a list of all the data sets originally written on that ML2 tape, but you would still need to look at the CDS data sets to determine which of those data sets on the physical ML2 tape were still active and not logically

Re: Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-13 Thread Mike Schwab
When we browsed a ML1 tape on dasd, we saw the real DSN at the start of each dataset. On Wed, Jul 13, 2022, 11:51 Nigel Morton wrote: > Two wildly different thoughts: > > 1. Might it be possible to mount the offending tape manually depending of > course on what's failed in the library? > 2.

Re: Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-13 Thread Joel C. Ewing
On the very rare occasion (like once in 15 years) where we really needed to recover data off a ML2 tape using backup CDS data sets, We ran our stand-alone "one-drive" test system in a SysProg test LPAR to restore the related CDS datasets, fire up DFHSM, recall the needed datasets off of the

Re: Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-13 Thread Allan Staller
Classification: Confidential Look up common recall queue -Original Message- From: IBM Mainframe Discussion List On Behalf Of Nigel Morton Sent: Wednesday, July 13, 2022 11:49 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Reading MCDS ML2 Tape on a different Lpar? Possible? [CAUTION

Re: Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-13 Thread Nigel Morton
Two wildly different thoughts: 1. Might it be possible to mount the offending tape manually depending of course on what's failed in the library? 2. DFSMShsm AUDIT MEDIACONTROLS once the tape has been transported to the main site. This probably involves less risk of bodily harm. On Wed, 13 Jul

Reading MCDS ML2 Tape on a different Lpar? Possible?

2022-07-12 Thread fred glenlake
Hello Listers, I have a small remote site that we are upgrading the physical tape library to a virtual TS7700 library. All went well until the old library had a serious hardware error. My leadership has decided not to spend the money to repair the old failed library (of course now out of