Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-12 Thread Kenneth J. Kripke
First off, thank you to all that responded to this inquiry. Some additional information: On our systems that are still running on the z/14 processor, the triplets, Offset, Length, and Count are all present in the SMF type 30 record. The products in question are using the unauthorized method

Re: Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-11 Thread Charles Mills
In my SMF experience ... If the triplet offset or count field is zero then the segment does not exist. End of story. If the triplet length field is zero then - For most SMF record types that means the segment does not exist. - For Db2, and perhaps a few other types, it means each segment contains

Re: Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-11 Thread Barry Merrill
Duh, Go to OFFSET and INPUT the LENGTH field. Barry -Original Message- From: IBM Mainframe Discussion List On Behalf Of Barry Merrill Sent: Friday, December 11, 2020 11:02 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Z15 zedc compression and CONNECT DIRECT, MFT compression It is very

Re: Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-11 Thread Barry Merrill
t: Re: Z15 zedc compression and CONNECT DIRECT, MFT compression If you are using MXG with SAS, its likely you might need an update there? _ Dave Jousma AVP | Director, Technology Engineering  F

Re: Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-09 Thread Jousma, David
  |  Grand Rapids, MI 49546 616.653.8429  |  fax: 616.653.2717 -Original Message- From: IBM Mainframe Discussion List On Behalf Of Kenneth J. Kripke Sent: Wednesday, December 9, 2020 12:52 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Z15 zedc compression and CONNECT DIRECT, MFT compression

Re: Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-09 Thread R.S.
W dniu 09.12.2020 o 18:52, Kenneth J. Kripke pisze: Hello; We have upgraded from a Z14 to Z15 processor, and, have experienced something curious regarding the SMF TYPE 30 section being generated for Connect Direct as well as Tibco's MFT 8.0 file transfer products. Both products are enable

Z15 zedc compression and CONNECT DIRECT, MFT compression

2020-12-09 Thread Kenneth J. Kripke
Hello; We have upgraded from a Z14 to Z15 processor, and, have experienced something curious regarding the SMF TYPE 30 section being generated for Connect Direct as well as Tibco's MFT 8.0 file transfer products. Both products are enabled to use ZEDC compression, but, when generating SAS