Re: Question on use of LPARNAME, SYSNAME and SMFID

2023-02-14 Thread Lennie Dymoke-Bradshaw
Interesting. I remember the SMFid being around on MVS 3.7 and 3.8. The Sysname (CVTSNAME) became more important with the advent of Sysplex so I probably remember using it from then. Wikipedia has MVS/SP dated as 1980. It was preceded by MVS/SE and before that by MVS 3.8. I don't think I used

determine job that created dataset?

2023-02-14 Thread Bill Giannelli
Is there a way to determine what job created a dataset? thanks Bill -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

DB2 DSNTRVFY WLM verify job stops WLM

2023-02-14 Thread Bill Giannelli
I am running the DB2 install job DSNTRVFY used to verify WLM Application Environments. It seems it stop some of my Application Environments. How could I find out why? I am posting here after not getting any responses on DB2-L. thanks for any help or direction. Bill

Re: determine job that created dataset?

2023-02-14 Thread Gadi Ben-Avi
SMF should have that information, if you collect it. -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bill Giannelli Sent: יום ג 14 פברואר 2023 12:29 To: IBM-MAIN@LISTSERV.UA.EDU Subject: determine job that created dataset? Is there a way to determine what job

Re: determine job that created dataset?

2023-02-14 Thread Bill Giannelli
Thank you for your response. Might you know the IFCID and the field? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: determine job that created dataset?

2023-02-14 Thread Gadi Ben-Avi
As far as I remember, It's SMF type 14 or 15, and maybe 60 for the catalog operation. I would use DAF to scan the SMF file and find the information. You can get DAF here https://sites.google.com/site/michaeljosephcleary/michael-joseph-cleary/zos-freeware Gadi -Original Message- From:

Sv: determine job that created dataset?

2023-02-14 Thread Lars Höglund
No access to that... -Ursprungligt meddelande- Från: IBM Mainframe Discussion List För Gadi Ben-Avi Skickat: den 14 februari 2023 12:03 Till: IBM-MAIN@LISTSERV.UA.EDU Ämne: Re: determine job that created dataset? As far as I remember, It's SMF type 14 or 15, and maybe 60 for the catalog

Re: determine job that created dataset?

2023-02-14 Thread Mike Shaw
On Tue, Feb 14, 2023, 5:29 AM Bill Giannelli wrote: > Is there a way to determine what job created a dataset > The job name is in the F8 DSCB in the VTOC entry for the dataset IF the dataset resides in the Extended Addressing Space (EAS) on an Extended Addressing Volume (EAV). Mike Shaw

Re: Sv: determine job that created dataset?

2023-02-14 Thread Radoslaw Skorupka
You can download it from cbttape.org Look for file 094. However you did not provide details. What dataset? VSAM or non-VSAM? Etc. The more details the better help you would get. -- Radoslaw Skorupka Lodz, Poland W dniu 14.02.2023 o 12:23, Lars Höglund pisze: No access to that...

Re: Question on use of LPARNAME, SYSNAME and SMFID

2023-02-14 Thread Burgess, Otto A. (CTR)
That was educational Thanks Al! -Original Message- From: IBM Mainframe Discussion List On Behalf Of Al Sherkow Sent: Monday, February 13, 2023 10:23 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Question on use of LPARNAME, SYSNAME and SMFID The 4-char SMFID has been around a very long

Re: Are JNI required to be re-entrant and/or re-usable?

2023-02-14 Thread Peter Relson
Steve Austin wrote >as the 1st call works and subsequent calls fail in the assembler routine. That's a bit surprising to me. It's usually concurrent calls that fail due to reentrancy issues of a non-reentrant module, not "subsequent calls". So while the concurrency case is quite possibly still

Re: Are JNI required to be re-entrant and/or re-usable?

2023-02-14 Thread Seymour J Metz
OP stated that it is not reusable. Regrettable, but he's stuck with it. Your guess of a DS that the code assumes is initialized seems plausible. -- Shmuel (Seymour J.) Metz http://mason.gmu.edu/~smetz3 From: IBM Mainframe Discussion List

zSecure class description

2023-02-14 Thread Radoslaw Skorupka
(This is not RACF question, so I addressed it here) zSecure option RA - RACF Administration, S Settings, then RACFCLAS show list of RACF classes. All the IBM-supplied classes have brief description. However user-defined classes have ??? instead. Question: is it possible to supply zSecure some

Re: Question on use of LPARNAME, SYSNAME and SMFID

2023-02-14 Thread Seymour J Metz
It goes back to OS/360. -- Shmuel (Seymour J.) Metz http://mason.gmu.edu/~smetz3 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of Lennie Dymoke-Bradshaw [032fff1be9b4-dmarc-requ...@listserv.ua.edu] Sent: Tuesday, February

how to read SMF data?

2023-02-14 Thread Bill Giannelli
when getting SMF records how do you actually read the data / fields? is there a common program/ job to access SMF data? thanks Bill -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to

Re: Question on use of LPARNAME, SYSNAME and SMFID

2023-02-14 Thread Seymour J Metz
The SMF id goes back to the SMF option of OS/360. -- Shmuel (Seymour J.) Metz http://mason.gmu.edu/~smetz3 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of Peter Relson [rel...@us.ibm.com] Sent: Monday, February 13, 2023 8:34

Re: how to read SMF data?

2023-02-14 Thread Seymour J Metz
If you're already licensed for SAS, get MXG. -- Shmuel (Seymour J.) Metz http://mason.gmu.edu/~smetz3 From: IBM Mainframe Discussion List [IBM-MAIN@LISTSERV.UA.EDU] on behalf of Bill Giannelli [billgianne...@gmail.com] Sent: Tuesday, February 14, 2023

Re: DB2 DSNTRVFY WLM verify job stops WLM

2023-02-14 Thread Keith Gooding
In my experience DB2 WLM environments are stopped because the associated started task failed - Eg abend or JCL error. Check the output and syslog. I also once forgot to copy the STC JCL from the proclib which I use for dB2 installation to a system proclib library so no STC output just a syslog

Re: how to read SMF data?

2023-02-14 Thread Bill Giannelli
is MXG a pay for product? -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Re: how to read SMF data?

2023-02-14 Thread Seymour J Metz
The last time I looked the price was ridiculously cheap, and if your already paying for SAS then the delta is negligible. You get a lot and the support is excellent (not a word I use a lot .) -- Shmuel (Seymour J.) Metz http://mason.gmu.edu/~smetz3

Re: DB2 DSNTRVFY WLM verify job stops WLM

2023-02-14 Thread Lance D. Jackson
Bill, Typically WLM appl. environments enter a stopped state due to a program error in one of the programs running in that address space. Are you certain that the specific WLM instances were in a normal state at the outset? It would be unusual for one of the Db2-supplied routines to have

Re: how to read SMF data?

2023-02-14 Thread Bill Giannelli
thank you for your responses! I just found out we have MXG! doing google searches. might you point me to a link and or manual on how to use MXG? thanks Bill -- For IBM-MAIN subscribe / signoff / archive access instructions,

Re: how to read SMF data?

2023-02-14 Thread Tom Marchant
mxg.com On Tue, 14 Feb 2023 09:10:04 -0600, Bill Giannelli wrote: >thank you for your responses! >I just found out we have MXG! >doing google searches. >might you point me to a link and or manual on how to use MXG? >thanks >Bill >

Re: determine job that created dataset?

2023-02-14 Thread Steve Beaver
Look at the 14 and 15 records Steve Beaver -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Gadi Ben-Avi Sent: Tuesday, February 14, 2023 4:37 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: determine job that created dataset? SMF

Befuddled

2023-02-14 Thread Steve Beaver
I am absolutely befuddled. These are the control cards I fed to IFASMFDL, and there are many 14's and 15's yet The OUDD has no records. Does anyone see any thing wrong? IFA010I SMF DUMP PARAMETERS IFA010I REPORTOPTS(NOSUBTYPE) -- DEFAULT IFA010I SIGSTRIP -- DEFAULT IFA010I

Re: how to read SMF data?

2023-02-14 Thread Steve Thompson
Since you have MXG, you should be able to get the doc for free from their website. I was just there checking on a few things.  https://www.mxg.com Regards, Steve Thompson On 2/14/2023 10:10 AM, Bill Giannelli wrote: thank you for your responses! I just found out we have MXG! doing google

Re: Befuddled

2023-02-14 Thread Itschak Mugzach
Are you looking for ty[pe 80 (or 30) records? If you, you did not specify them in the selection criteria. ITschak *| **Itschak Mugzach | Director | SecuriTeam Software **|** IronSphere Platform* *|* *Information Security Continuous Monitoring for Z/OS, zLinux and IBM I **| * *|* *Email**:

Re: Befuddled

2023-02-14 Thread Steve Beaver
I'm really looking for 14,15's but I did not change the JCL -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Itschak Mugzach Sent: Tuesday, February 14, 2023 9:59 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Befuddled Are you

Re: [EXTERNAL] Re: Befuddled

2023-02-14 Thread Pommier, Rex
Are your dates off? > IFA834I RELATIVEDATE PARAMETER RESULTS IN START DATE 2023.044, END > > DATE 2023.044 > >SUMMARY ACTIVITY REPORT > > START DATE-TIME 02/14/2023-06:00:00 END > DATE-T DATE=23.044 =

Re: [EXTERNAL] Re: Befuddled

2023-02-14 Thread Steve Beaver
This SYSIN is correct RELATIVEDATE(BYDAY,01,01) which says yesterday and today -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Pommier, Rex Sent: Tuesday, February 14, 2023 10:10 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re:

Re: determine job that created dataset?

2023-02-14 Thread Bruce Hewson
Hi Bill, my MXG code:- options ls=160 ; MACRO STOPOVER MISSOVER %

Re: [EXTERNAL] CLIST for APF and link list datasets

2023-02-14 Thread Lionel B Dyck
Perhaps TASID? Lionel B. Dyck < Website: www.lbdsoftware.com Sent from my iPhone 12 Pro Worry more about your character than your reputation. Character is what you are, reputation merely what others think you are." - John Wooden > On Feb 14, 2023, at 4:05 PM, Bill Giannelli wrote: > > no,

Re: [EXTERNAL] CLIST for APF and link list datasets

2023-02-14 Thread Steve Smith
IPLINFO is a great exec, but I'd say the best display is from SDSF APF and LNK commands. Sort by any column. It may have something for LLA, idk. I recently found LPD (Link Pack Directory), which is very helpful (and cool). It pays to check the SDSF command menu now & then. Rob Scott's been

Sv: CLIST for APF and link list datasets

2023-02-14 Thread Lars Höglund
And with parm like LINK / APF / LPA (or without parm) -Ursprungligt meddelande- Från: IBM Mainframe Discussion List För rpinion865 Skickat: den 14 februari 2023 20:56 Till: IBM-MAIN@LISTSERV.UA.EDU Ämne: Re: CLIST for APF and link list datasets DDLIST from any ISPF command line.

Re: NJE over IP

2023-02-14 Thread Steve Horein
What's going on with your message IDs? Why do they end with a "1" in place of an "I"? On Tue, Feb 14, 2023 at 8:47 PM Steve David wrote: > Hello, > > We had some issue setting up NJE over Ip, It's a multi-stack environment > (TCPIPA1 & TCPIPA2), we had problem using(Nat) ip and port 175.

Re: [EXTERNAL] CLIST for APF and link list datasets

2023-02-14 Thread Bill Giannelli
no, it had a menu of almost all the entries in z/OS with APF and LLA amongst them. It might have been a third party software -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to

Re: [EXTERNAL] CLIST for APF and link list datasets

2023-02-14 Thread Pommier, Rex
Are you thinking of ISRDDN?TSO ISRDDN APF for example? -Original Message- From: IBM Mainframe Discussion List On Behalf Of Bill Giannelli Sent: Tuesday, February 14, 2023 1:47 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: [EXTERNAL] CLIST for APF and link list datasets I was shown a

Re: [EXTERNAL] CLIST for APF and link list datasets

2023-02-14 Thread David Spiegel
Hi Bill, Maybe OMEGAMON or SYSVIEW? Regards, David On 2023-02-14 17:04, Bill Giannelli wrote: no, it had a menu of almost all the entries in z/OS with APF and LLA amongst them. It might have been a third party software

NJE over IP

2023-02-14 Thread Steve David
Hello, We had some issue setting up NJE over Ip, It's a multi-stack environment (TCPIPA1 & TCPIPA2), we had problem using(Nat) ip and port 175. Netsrv1 couldn't bind to port 175. We did verified that port 175 was not in use from both the stacks. IAZ05451 NETSRV1 Error encountered in function

Re: [EXTERNAL] Re: Impact or got'cha's on changing SYSNAME

2023-02-14 Thread Mike Schwab
You can add the new ID to the SMS definitions before the change then remove the old value after. Our site did do a removal. On Tue, Feb 14, 2023 at 10:40 AM Pommier, Rex wrote: > > Hi Al, > > Thanks for the SCRT information. As far as how to change it, I would be > looking at doing it at an

Re: [EXTERNAL] Re: Impact or got'cha's on changing SYSNAME

2023-02-14 Thread Pommier, Rex
Hi Al, Thanks for the SCRT information. As far as how to change it, I would be looking at doing it at an IPL , definitely. One of my coworkers says she tried it some time ago (probably years ago) and had SMS issues after changing it. IDK if she changed it at an IPL or how she tried, but

Impact or got'cha's on changing SYSNAME

2023-02-14 Thread Pommier, Rex
Hi, I've been following the thread on LPARNAME, SYSNAME and SMFID with interest, namely because of a naming issue at my site that has been a minor irritation for me for years. We run a small shop, 2 production LPARs not in a sysplex. One of the LPARs is set up as SYSNAME=SMFID=ZOS1.

Re: Impact or got'cha's on changing SYSNAME

2023-02-14 Thread Al Sherkow
I don't consider myself a "systems programmer" any longer... I assume the only safe way to do this is with an IPL. I don't know if changing this dynamically is an option. There will be no issue with SCRT. SYSNAME is in both the SMF 70 and SMF 89 records that SCRT processes. SCRT can handle

Re: [EXTERNAL] Re: Befuddled

2023-02-14 Thread Pommier, Rex
We don't use SMF logstreams so I have never used relativedate, it just seems odd to me that your output is saying that the start date = end date = yesterday. Just for kicks, what happens if you change the parameter to be RELATIVEDATE(BYDAY,01,02)? Does the calculated date change? The doc

Re: Question on use of LPARNAME, SYSNAME and SMFID

2023-02-14 Thread Al Sherkow
I had problems to solve to combine old SMF records (0/IPL, 90(5A)/System Status) when 4-char SMFID/SYSPLEX/SYSNAME are duplicated on different machines as the CPUTYPE and serial number are not in most of the SMF records. I did ask IBM to add those to the SMF header some time ago. I think

Re: [EXTERNAL] how to read SMF data?

2023-02-14 Thread Pommier, Rex
Hi Bill, We have a daily job that uses a home-grown Cobol program to parse the SMF data. We report on types 14, 15, 17, 18, 61, 62, 64-66 to get changes made to both VSAM and non-VSAM datasets. I will probably go look at the CBT program that Radoslaw mentioned, just from curiosity, to see

Re: how to read SMF data?

2023-02-14 Thread Gibney, Dave
MXG is a source available product. And, just about all the documentation in that source lib. It's a bit massive and perhaps overwhelming. SRCHFOR helps > -Original Message- > From: IBM Mainframe Discussion List On > Behalf Of Bill Giannelli > Sent: Tuesday, February 14, 2023 7:10 AM >

Re: CLIST for APF and link list datasets

2023-02-14 Thread Bill Giannelli
no, it's a clist executed via "TSO (clist name)" -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

CLIST for APF and link list datasets

2023-02-14 Thread Bill Giannelli
I was shown a clist that had various options to display things like APFs and LLA, etc. I am struggling to remember the clist name to run. I am hoping this vague question sparks someone's memory. does anyone know the clist? thanks Bill

Re: CLIST for APF and link list datasets

2023-02-14 Thread Itschak Mugzach
IPL info בתאריך יום ג׳, 14 בפבר׳ 2023 ב-21:47 מאת Bill Giannelli < billgianne...@gmail.com>: > I was shown a clist that had various options to display things like APFs > and LLA, etc. > I am struggling to remember the clist name to run. > I am hoping this vague question sparks someone's memory.

Re: CLIST for APF and link list datasets

2023-02-14 Thread rpinion865
DDLIST from any ISPF command line. Sent with Proton Mail secure email. --- Original Message --- On Tuesday, February 14th, 2023 at 2:47 PM, Bill Giannelli wrote: > I was shown a clist that had various options to display things like APFs and > LLA, etc. > I am struggling to

Re: CLIST for APF and link list datasets

2023-02-14 Thread Lionel B. Dyck
IPLINFO from CBTTape File 434. There is also SHOWZOS from CBTTAPE File 492 and 614. Both can be found at https://www.cbttape.org but always check here https://cbttape.org/updates.htm first. A good tool, if you have FTP access from your z/OS system to ftp.cbttape.org is found in CBTTAPE File

Re: CLIST for APF and link list datasets

2023-02-14 Thread Itschak Mugzach
http://mzelden.com/mvsfiles/iplinfo.txt בתאריך יום ג׳, 14 בפבר׳ 2023 ב-21:51 מאת Bill Giannelli < billgianne...@gmail.com>: > no, it's a clist executed via "TSO (clist name)" > > -- > For IBM-MAIN subscribe / signoff / archive

Re: CLIST for APF and link list datasets

2023-02-14 Thread Lionel B. Dyck
Both IPLINFO and SHOWZOS are invoked from ISPF using the command TSO Lionel B. Dyck <>< Website: https://www.lbdsoftware.com Github: https://github.com/lbdyck “Worry more about your character than your reputation. Character is what you are, reputation merely what others think you are.”

zOSMF

2023-02-14 Thread rpinion865
I'm attempting to use the Portable Software Instance dialog to retrieve an IBM order. This is for a z/OS 2.4 system. I've reached a point where I don't know where to look to correct the problem I am having. I'm receiving IZUG1040E when I attempt to submit the generated job. I've run the sample