Re: RFE opened on IEBGENER and PDS Corruption

2016-06-19 Thread פנינה קוניגסברג
Oh, how I wish that was true. Tried many of the suggestions posted both before and after I submitted the problem. Iebgener to different size pds`s 80 & 124. Today, Printds looked good but same results. Xmit/receive today really made me hopeful but alas the output file still remained with io

Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption

2016-06-19 Thread פנינה קוניגסברג
Yes - definitely - but I think I went wrong when I edited the output . . -Original Message- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Jesse 1 Robinson Sent: Sunday, June 19, 2016 6:35 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: [EXTERNAL] RFE

Re: [EXTERNAL] RFE opened on IEBGENER and PDS Corruption

2016-06-19 Thread פנינה קוניגסברג
Thanks so much Lizette and Lionel. In my case, it was SYSPRINT of IDCAMS that 'reconfigured' the PDS file, followed by edit of the sysprint output members. Believe me , the 'sandbox' is now backed up daily. . -Original Message- From: IBM Mainframe Discussion List

Re: Read a PDS (all members) like PS dataset

2016-06-15 Thread פנינה קוניגסברג
Thanks for the amazingly rapid reply. A little bit more info : the original dcb was lrecl=80, blksize=27290, recfm=fb dsorg=po. The file as modified by IDCAMS is lrecl=125, blksize =27920,recfm=vba,dsorg=po Built 2 sequential output files, each with the dcb paramaters of before & after

Re: Read a PDS (all members) like PS dataset

2016-06-15 Thread פנינה קוניגסברג
Always interesting, I am dealing this week with an error that I hoped would be solved by the different solutions presented here, but after trying some of the solutions presented herein have not recovered. Background: In preparation for a system cutover, executed IDCAMS LISTC with SYSPRINT to

Re: IEASYMxx in DR

2014-02-17 Thread פנינה קוניגסברג
The use of indirect references allows for modifying the symbolics dynamically 'artificially' i.e. SYMDEF(SYSF0='SYSR1(1:4).SYSFZOS.0') Penina Koenigsberg P 972-2-5602354  972-58-6540737 9 penin...@education.gov.il -Original Message- From: IBM Mainframe Discussion List