These are STCK values, if I remember correctly. As are most of the fields
in both IFCID 003 and 239 variants of the Accounting Trace (SMF 101)
record.
And your timing difficulties might be related to the fact these are
package-level (QPAC section) timings, not plan-invocation timings
(typically QWAC).
Cheers, Martin
Martin Packer,
zChampion, Principal Systems Investigator,
Worldwide Banking Center of Excellence, IBM
+44-7802-245-584
email: martin_pac...@uk.ibm.com
Twitter / Facebook IDs: MartinPacker
Blog:
https://www.ibm.com/developerworks/mydeveloperworks/blogs/MartinPacker
From: Keller, Ted ted.kel...@yrcfreight.com
To: IBM-MAIN@listserv.ua.edu,
Date: 10/24/2012 12:31 PM
Subject:Need help parsing DB2 Accounting trace data
Sent by:IBM Mainframe Discussion List IBM-MAIN@listserv.ua.edu
I am trying to determining what the values mean in the CPU (QPACTJST) and
elapsed time (QPACSCT) fields in ICFID 239 accounting trace data. I have
not been able to find anything that indicates what units (e.g.,
milliseconds, microseconds, etc.) these values represent. I also noted
that
there does not seem to be any correlation in the difference between
starting
and ending store clock values (QPACSCB and QPACSCE) and the reported
elapsed
time (QPACSCT) or the difference between entry and exit CPU times
(QPACBJST
AND QPACEJST) and reported CPU time (QPACTJST).
Ted Keller
YRC Freight, Inc
913-344-3274
ted.kel...@yrcfreight.com
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN
Unless stated otherwise above:
IBM United Kingdom Limited - Registered in England and Wales with number
741598.
Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU
--
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN