Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-09 Thread Scott Fagen
On Tue, 8 Oct 2013 17:38:02 +0300, Sheldon Davis wrote: I was wondering what the maximum distance would be for a Parallel Sysplex with DB2 Data Sharing on two BC12's. From http://www-03.ibm.com/systems/z/advantages/gdps/faqs.html How far apart can I spread my CF's? How far can I stretch my

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-09 Thread Rob Schramm
The only comment is that the km or miles start to add up when a signal to a CF has to make the round trip there and back again. When looking at response times .. distance can make a difference. In general... the fact that this stuff can be done is just really cool. Rob Schramm On Oct 9, 2013

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-09 Thread Martin Packer
/developerworks/mydeveloperworks/blogs/MartinPacker From: Rob Schramm rob.schr...@gmail.com To: IBM-MAIN@listserv.ua.edu, Date: 09/10/2013 18:56 Subject:Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing Sent by:IBM Mainframe Discussion List IBM-MAIN

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-09 Thread Skip Robinson
SHARE MVS Program Co-Manager 626-302-7535 Office 323-715-0595 Mobile jo.skip.robin...@sce.com From: Rob Schramm rob.schr...@gmail.com To: IBM-MAIN@LISTSERV.UA.EDU, Date: 10/09/2013 10:57 AM Subject:Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing Sent

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-09 Thread efinnell15
There was a great SHARE presentation in early nineties of one site that built a data center a few miles across the valley with their own fiber only to have the highway department come along and blew off a section for road widening. They had to pull across old train trestles and abandoned mines

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-09 Thread nitz-...@gmx.net
OTOH I would not entertain running a parallel sysplex over DWDM. A former employer did. Distance about 22km. Due to IBMs requirement for parallel sysplex pricing for at least one machine being on a different box. That distant lpar was (obviously) sharing ISGLOCK, and response times from

Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-08 Thread Sheldon Davis
Hi I was wondering what the maximum distance would be for a Parallel Sysplex with DB2 Data Sharing on two BC12's. Thanks Sheldon Davis -- For IBM-MAIN subscribe / signoff / archive access instructions, send email to

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-08 Thread Rob Schramm
I know that 13 miles works. Rob On Oct 8, 2013 10:38 AM, Sheldon Davis sda...@isracard.co.il wrote: Hi I was wondering what the maximum distance would be for a Parallel Sysplex with DB2 Data Sharing on two BC12's. Thanks Sheldon Davis

Re: Distance considerations fo a Parallel Sysplex with DB2 Data Sharing

2013-10-08 Thread John Eells
Sheldon Davis wrote: Hi I was wondering what the maximum distance would be for a Parallel Sysplex with DB2 Data Sharing on two BC12's. I'd think it would be the same as the general 100km separation limit for a Parallel Sysplex. However, the maximum practical distance depends at least