Re: IEC331I 042-006 occurs during GDG roll in process

2019-02-18 Thread Frank Swarbrick
A.EDU Subject: Re: IEC331I 042-006 occurs during GDG roll in process Thanks, Rob. I think the first thing I'll have tried (if ops will do it!) is perform a WHOHAS on the dataset. This should tell me who/what has the dataset enqueued, right? Frank From: IBM

Re: IEC331I 042-006 occurs during GDG roll in process

2019-02-18 Thread Frank Swarbrick
riday, February 15, 2019 5:30 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: IEC331I 042-006 occurs during GDG roll in process One more thing, is it possible for this job that runs that many times per day to contend with itself occasionally (i.e. demand-triggered with varying job name or duplicate-jo

Re: IEC331I 042-006 occurs during GDG roll in process

2019-02-15 Thread Jackson, Rob
: Jackson, Rob Sent: Friday, February 15, 2019 7:20 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: RE: IEC331I 042-006 occurs during GDG roll in process Hah, our emails waived at each other as they were being delivered. But it would be weird if someone were always browsing the last generation when this

Re: IEC331I 042-006 occurs during GDG roll in process

2019-02-15 Thread Jackson, Rob
2019 7:10 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: IEC331I 042-006 occurs during GDG roll in process [External Email] The long result code (040B0425) seems to mean "Verify DADSM SCRATCH request; enqueue on SYSDSN failed." What can cause this to occur? Someone perhaps had the datase

Re: IEC331I 042-006 occurs during GDG roll in process

2019-02-15 Thread Jackson, Rob
nk Mainframe Technical Support -Original Message- From: IBM Mainframe Discussion List On Behalf Of Frank Swarbrick Sent: Friday, February 15, 2019 6:32 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: IEC331I 042-006 occurs during GDG roll in process [External Email] We have a job that runs doze

Re: IEC331I 042-006 occurs during GDG roll in process

2019-02-15 Thread Frank Swarbrick
Swarbrick Sent: Friday, February 15, 2019 4:31 PM To: IBM-MAIN@LISTSERV.UA.EDU Subject: IEC331I 042-006 occurs during GDG roll in process We have a job that runs dozens of times per day, copying a circular log file to a GDG backup. On occasion we get something like the following: IEC33

IEC331I 042-006 occurs during GDG roll in process

2019-02-15 Thread Frank Swarbrick
We have a job that runs dozens of times per day, copying a circular log file to a GDG backup. On occasion we get something like the following: IEC331I 042-006(040B0425),INIT,MICR01PR,SCRT,IGG0CLH0 IEC331I VOL,BK0068,NAME,PROD.XMTIN.MICR.MICRDLY.BKP.G1514V00 The issue does not cause the jo