Thank for all who gave guide, I learned new things
Mohamed
Sent from my iPad
> On Mar 17, 2017, at 2:58 PM, Dana Mitchell wrote:
>
> Nick,
> That's an excellent document, I had not seen that before. Saved for future
> reference.
>
> Thanks,
> Dana
>
>> On Fri, 17 Mar
Thanks a lot Nick, it is very useful Doc
Mohamed
Sent from my iPad
> On Mar 17, 2017, at 12:22 PM, Nick G wrote:
>
> Take a look at white paper WP102314 at http://www.ibm.com/support/techdocs
>
> This gives you various options of merging CTNs either disruptively or
>
Nick,
That's an excellent document, I had not seen that before. Saved for future
reference.
Thanks,
Dana
On Fri, 17 Mar 2017 04:22:56 -0500, Nick G wrote:
>Take a look at white paper WP102314 at http://www.ibm.com/support/techdocs
>
W dniu 2017-03-17 o 07:36, Mohamed Gomaa pisze:
It locks that, I did not ask the question properly. What I want to see do I
have to stop in previous all the LPARs getting the time from this CTN, because
I feel if any LPAR see that the CTN name changed it may have some corruption
To clarify:
Take a look at white paper WP102314 at http://www.ibm.com/support/techdocs
This gives you various options of merging CTNs either disruptively or
non-disruptively, I successfully used the non-disruptive approach last year
having studied this paper very carefully.
It locks that, I did not ask the question properly. What I want to see do I
have to stop in previous all the LPARs getting the time from this CTN, because
I feel if any LPAR see that the CTN name changed it may have some corruption
Sent from my iPhone
> On Mar 16, 2017, at 8:49 PM, Dana
You shouldn't have to stop them (the CEC's themselves) as long as you can get
all the timing links active first. Any LPARs that want to join the sysplexes
will need re-ipled if the timesource changes.
On Thu, 16 Mar 2017 20:45:30 +0300, Mohamed Gomaa wrote:
>Hi Dana,
>Do I
Hi Dana,
Do I have to stop the two CECs first before do the change.
Mohamed
Sent from my iPhone
> On Mar 16, 2017, at 8:00 PM, Dana Mitchell wrote:
>
> Mohamed,
>
> You will have to change the CTN on the DR CEC and the TEST CEC to PRODSTP.
> Then I think all LPARs on
Mohamed,
You will have to change the CTN on the DR CEC and the TEST CEC to PRODSTP.
Then I think all LPARs on those two CECs will need to be IPLed to be aware of
the new time source. It's been a while since we've change any of our STP
configuration.
Dana
On Thu, 16 Mar 2017 06:20:07 +,
Hi dear We are right now in project of Disaster Recovery Site, we have
only one CEC in DR to combined both TEST and PROD, in HO three CECs for PROD,
and one CEC for TEST.The PROD in one CTN STP called (PRODSTP) the TEST
environment in Active/Active between the two sites in one Sysplex
Hi dear We are rightnow in project of Disaster Recovery Site, we have only
one CEC in DR tocombined both TEST and PROD, in HO three CECs for PROD, and one
CEC forTEST.The PROD in one CTN STP called (PRODSTP) the TEST environmentin
Active/Active between the two sites in one Sysplex using one
11 matches