Hi all,
Can the EXAFS of the L1 edge of 3rd row transition elements be analyzed? I've
never tried it, and the discussion so far has been for the L2 and L3 edges. I
know there would be some interference from the EXAFS of the lower edges, but
that's just a technical problem, and can be corrected
Hi,
in Athena you can still normalize data, plot together, etc, but due to
that lines L2 and L3 are very closed you will observe no EXAFS oscillations.
In opposite I use Athena and Artemis to analyse EXAFS on e.g. O K edge
L edges for EXAFS are useful for mainly 5d and actined elements...
reg
You can process the data but the L3-edge for 1st row transition elements
(Mn and Ni) is only separated by 10-15 eV from the L2 edge so EXAFS
analysis is not possible.
good luck,
Chris
Christopher J. Patridge, PhD
NRC Post Doctoral Research Associate
Naval Rese
I have never used Athena to work up soft x-ray data, but I assume it is
possible. But you run into issues of not having enough pre- or post-edge
data points to do a proper Athena-type normalization. Bruce and co. have
discussed this many times on this list. .
Beside this, fitting your early tra
Hi,
I am a research student and relatively new to XAFS. I have soft X-Ray
L-edge data of Mn and Ni. Is it possible to process this data in Athena and
then fit in Artemis like usual K-edge data?
Thanks
--
Shoaib
___
Ifeffit mailing list
Ifeffit@millenia