Igor
Simon
-Original Message-
From: ifeffit-boun...@millenia.cars.aps.anl.gov
[mailto:ifeffit-boun...@millenia.cars.aps.anl.gov] On Behalf Of Eva Vanamee
Sent: Tuesday, March 26, 2013 3:51 PM
To: ifeffit@millenia.cars.aps.anl.gov
Subject: [Ifeffit] plotting
Thanks everyone for the hel
POSTDOCTORAL POSITION in XAFS and XRD
UOP LLC
There is a potential opening for a postdoctoral position in synchrotron
radiation research of catalysts and adsorbents with UOP LLC. The
successful candidate with work with UOP LLC research scientists and will
support UOP LLC exploratory and fundamenta
Edward:
For rhenium the examples published in the literature use the first
inflection point to define the oxidation state. Indeed for a set of
rhenium oxides of formal oxidation state 4, 6 and 7 there is close to a
linear relationship of formal oxidation state with edge position. We
have collected
All:
Please see the job posting for an immediate Postdoctoral Position at SSRL for
in-situ Catalysis X-ray Absorption Spectroscopy
https://careers.slac.stanford.edu/sites/careers.slac.stanford.edu/files/Postdoctoral%20Position%20SSRL%20Catalysis%20Research.pdf
Postdoctoral Position at SSRL for
SUNCAT Postdoctoral Position for Synchrotron X-ray Science
A postdoctoral research position is available at SUNCAT at SLAC National
Accelerator Laboratory. The position is available immediately to work on a
project developing and optimizing data processing techniques, and guiding
students and p
Please see the attached postdoctoral positon available now at SSRL.
It is also posted here:
https://careers.slac.stanford.edu/sites/careers.slac.stanford.edu/files/Postdoc_SSRL_Catalysis_Research_2018.pdf
Thanks!
Simon R Bare
Distinguished Staff Scientist
SSRL, MS69
SLAC National Accelerator Lab
There is an opening for a postdoctoral research associate positon in the fall
of 2019 at Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC National
Lab.
This postdoctoral position will involve using in-situ/in-operando
synchrotron-based methods, primarily X-ray absorption spectroscopy (
Talking of websites does anyone know what happened to the International XAFS
website? I can't access it. And what is going on with this organization?
Thanks.
Simon
___
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.
All:
We are wondering if others agree that the reported values for the W L3 and W L2
edges are incorrect. We recently noticed the following:
The "Edge" - defined by the inflection point of the absorption edge step
When using the Ir L3 edge (11215.0 eV) as a calibration, the W L3- and L2-edges