Dear Robert,
sorry for the late reply, life...
Brilliant suggestion!
I will let you know the results if the proposal is approved.
Best regards, euG
If you can move between Nd L3 and Br K, why not stop at Nd L1 if you
want to see if a Nd s-type initial state
has any influence on the XEOL? You
If you can move between Nd L3 and Br K, why not stop at Nd L1 if you
want to see if a Nd s-type initial state
has any influence on the XEOL? You should not need to go up to Nd K.
Some references:
https://aip.scitation.org/doi/abs/10.1063/1.477320?journalCode=jcp
Hi all,
I am planning XEOL measurements and I have a doubt.
My system is Nd coordinated to Eosin, tetrabromofluorescein. I want to
measure XEOL exciting on the Br K-edge (13.4keV) and the Nd L3-edge(6.2keV)
and measure the emission spectra of the dye and the Nd. I just measured the
emission of the