[Ifeffit] nonsensical negative values / restrictions

2017-06-15 Thread Felix E. Feiten
Dear all, I have the following problem: In some fits using Artemis (Demeter 0.9.25) I will get negative values for parameters where it makes no sense at all. For example, when trying to fit two first shell paths, Pt-Pt and Pt-O, for a Pt nanoparticle, sigma^2 for the Pt-O path becomes negativ

[Ifeffit] Automatically doing many fits / Scripting

2017-06-16 Thread Felix E. Feiten
Dear Ifeffit mailing-list, first of all sorry for writing another mail to the list in such a short time span, I hope people will not get sick of me too quickly. I want to do many fits for the same data with varying start-parameters. More specifically, I am doing fits to EXAFS data of the Pt L

Re: [Ifeffit] Automatically doing many fits / Scripting - Clarification

2017-06-16 Thread Felix E. Feiten
I am very sorry, in the second paragraph the sequence describing what I want to do could have been clearer: I want to 1. start a fit with certain parameters, 2. save the log file, 3. change one parameter. This should be repeated many (120 for now) times. Felix On 16/06/2017 18:39, Felix E

Re: [Ifeffit] nonsensical negative values / restrictions

2017-06-23 Thread Felix E. Feiten
pplying a weird parameter value. Or maybe you have a sulfide instead of the oxide you were expecting. Or maybe you ran Feff for the Pt K edge rather than the Pt L3 edge. (Oops! I actually do that with embarrassing frequency) Or something else I haven't thought of HTH, B On 0

Re: [Ifeffit] Automatically doing many fits / Scripting - Solved

2017-06-23 Thread Felix E. Feiten
epSize } ; target #1: PtCoN NP bC } CurPar1:=CurPar1+StepSize } Sleep 1000 MsgBox A total of %TFC% fits have been performed. Return } On 16/06/2017 18:59, Felix E. Feiten wrote: I am very sorry, in the second paragraph the sequence describing

[Ifeffit] Nearest neighbor statistics in a random alloy

2017-06-23 Thread Felix E. Feiten
Dear all, I am fitting a Pt9Co1 foil sample. I assume the sample to be basically fcc platinum with every 10th atom randomly replaced by cobalt. Here are the assumptions I make: 1. every atom has 12 nearest neighbors 2. every Pt atom has (on average) 10.7 Pt nearest neighbors and 1.3 Co near

Re: [Ifeffit] Nearest neighbor statistics in a random alloy

2017-06-23 Thread Felix E. Feiten
NCo-Pt/NCo-Co=9, Then you can get NPt-Pt=10.8, and NPt-Co=1.2 The results will be different if the structure is ordered. Regards, On Fri, Jun 23, 2017 at 9:02 AM, Felix E. Feiten mailto:fei...@cat.hokudai.ac.jp>> wrote: Dear all, I am fi

[Ifeffit] Exporting Curves (as Data rather than Images)

2017-06-26 Thread Felix E. Feiten
Dear all, I think the title is almost enough explanation. I would like to export the data corresponding to fits, chi(k), fourier-transform and back-transform to plot them with a different software. I couldn't figure out how, can someone please help me? With kind regards Felix

Re: [Ifeffit] Exporting Curves (as Data rather than Images)

2017-06-26 Thread Felix E. Feiten
B -- Regards, Guanghui At 2017-06-26 02:36:16, "Felix E. Feiten" wrote: Dear all, I think the title is almost enough explanation. I would like to export the data corresponding to fits, chi(k), fourier-transform and back-transform to plot them with a different software. I c

Re: [Ifeffit] smoothing XAS data

2020-01-23 Thread Felix E. Feiten
on, I would suggest never smoothing, instead showing the back-transform from R-space to q-space if you want to have nice looking curves but your data are not that good but ALWAYS supplying raw data in publications. With kind regards, Felix -- Dr. Felix E. Feiten Fritz-Haber-Institut der Max-Planc