Hi Chris,
I have a MX960 with Junos 10.4R1.9 and I have the same problem, I have to do
a restart of chassis-control process and the alarmas was cleared.
I hope to have help you.
---
David
On Mon, May 2, 2011 at 1:03 AM, Brent Jones br...@servuhome.net wrote:
On Sun, May 1, 2011 at 6:00 PM,
On Sun, May 1, 2011 at 6:00 PM, Chris Kawchuk juniperd...@gmail.com wrote:
Heh. Good question! I just had to double check:
show config system
commit synchronize;
Thats in there.. OK let's try it manually.
ckawchuk@jmx480# commit synchronize and-quit
re0:
configuration
Hi Paul..!
Yeah - I tried that as well initially with no luck (and just tried again
just now...)
me@wowter show configuration chassis
alarm {
management-ethernet {
link-down ignore;
}
}
user@wowter show chassis alarms
1 alarms currently active
Alarm time Class
Silly question... You did use commit sync, correct?
Will O'Brien
On May 1, 2011, at 7:51 PM, Chris Kawchuk juniperd...@gmail.com wrote:
Hi Paul..!
Yeah - I tried that as well initially with no luck (and just tried again
just now...)
me@wowter show configuration chassis
alarm {
Heh. Good question! I just had to double check:
show config system
commit synchronize;
Thats in there.. OK let's try it manually.
ckawchuk@jmx480# commit synchronize and-quit
re0:
configuration check succeeds
re1:
commit complete
re0:
commit complete
Exiting configuration
5 matches
Mail list logo