On 09/29/2014 11:43 AM, Bimow Chen wrote:
Register 0x800048 is not dB measure but relative scale. Fix it and conform to
NorDig specifications.
eh, 0x800048 register returned strength normalized to 0-100 %. But that
was earlier when older firmwares used. I have seen it does not return
On 09/29/2014 03:02 PM, Antti Palosaari wrote:
On 09/29/2014 11:43 AM, Bimow Chen wrote:
Register 0x800048 is not dB measure but relative scale. Fix it and
conform to NorDig specifications.
eh, 0x800048 register returned strength normalized to 0-100 %. But that
was earlier when older