Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-05 Thread Vince Hoang
On Fri, Dec 05, 2003 at 10:22:56AM -1000, Warren Togami wrote: > IMHO Videl does not need the extra disk capacity and the money > for 2x160GB disks would be much better spent in 250GB+ sized > disks for the mirror array. We need to reach around the $1,100 > mark if we will be able to buy 1TB of sto

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-05 Thread Warren Togami
On Fri, 2003-12-05 at 09:27, Matthew John Darnell wrote: > Vince, > > Is their a particular drive you have in mind, or just any 160GB disk. > > -Matt If this is to make Videl's system drive 2x160GB RAID1, then the identical brand and model would be ideal. IMHO Videl does not need the extra disk

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-05 Thread Vince Hoang
On Fri, Dec 05, 2003 at 09:27:26AM -1000, Matthew John Darnell wrote: > Is their a particular drive you have in mind, or just any 160GB disk. I am taking this off-list to expedite things. -Vince

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-05 Thread Matthew John Darnell
Vince, Is their a particular drive you have in mind, or just any 160GB disk. -Matt - Original Message - From: "Vince Hoang" <[EMAIL PROTECTED]> To: <[EMAIL PROTECTED]> Sent: Thursday, December 04, 2003 12:49 PM Subject: Re: [luau] videl.ics.hawaii.edu disk fail

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Thomas Ryan Gordon Sr
-BEGIN PGP SIGNED MESSAGE- Hash: SHA1 Vince Hoang wrote: | 3ware controller would be ideal if we stuck with an ATA solution. | | The others are not really hardware RAID providers at all. I guess that means the $20 figure jumps up to >$60 to do that. Also, the card looks alot bigger and

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Vince Hoang
On Thu, Dec 04, 2003 at 11:45:48AM -1000, Warren Togami wrote: > R.Scott Belford wrote: > >With time, though, enough money will be gathered to buy > >a matching larger drive ($177), and hopefully more. When > >that time comes we can move to faster drives as Vince has > >suggested. The 160gb drive h

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Vince Hoang
On Thu, Dec 04, 2003 at 10:32:54AM -1000, Thomas Ryan Gordon Sr wrote: > Does videl have an available PCI slot? If we still got the > low-end 60G (and it still fits) and spent $20 on a ATA RAID > controller we could stop doing the software RAID thing > and improve performance and reduce CPU usage.

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Brian Chee
[luau] videl.ics.hawaii.edu disk failure - Your Help Needed > Brian Chee wrote: > > > Beware, I've just been burned by the Promise ATA/133 RAID controller...it > > will only rebuild the array if you give a new drive of identical > > geometryunlike SCSI based

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Warren Togami
R.Scott Belford wrote: This was my motivation in buying a larger drive. If installed now, it solves redundancy issues but is not a true permanent solution. Software raid with different sized drives has a few more steps, I guess, with formatting, but this is not a big deal, is it? With time

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Warren Togami
Brian Chee wrote: Beware, I've just been burned by the Promise ATA/133 RAID controller...it will only rebuild the array if you give a new drive of identical geometryunlike SCSI based raid which only need a similar or larger sized drive. I'm exploring 3ware's offerings and am enthusiastic ab

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread R.Scott Belford
On Wednesday, December 3, 2003, at 09:17 AM, Vince Hoang wrote: On Tue, Dec 02, 2003 at 08:31:44PM -1000, R. Scott Belford wrote: Is priority one to replace the failed drive for this array? If so, what size? I can order it tomorrow. I am assuming that it needs to match the other 120gb drive I d

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Brian Chee
t: Thursday, December 04, 2003 10:32 AM Subject: Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed > -BEGIN PGP SIGNED MESSAGE- > Hash: SHA1 > > R.Scott Belford wrote: > > | I am saddened > > Don't be sad, I was just learning that the RAID is in-

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Thomas Ryan Gordon Sr
-BEGIN PGP SIGNED MESSAGE- Hash: SHA1 R.Scott Belford wrote: | I am saddened Don't be sad, I was just learning that the RAID is in-fact software-based and all 160 gigs will be usable. The more hard-drives, the merrier. But back to the tech stuff. I just had a thought about videl but

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread R.Scott Belford
On Thursday, December 4, 2003, at 01:16 AM, Warren Togami wrote: 160GB 7200rpm 8MB cache 60GB 7200rpm 2MB cache Unfortunately this means that Videl will still be limited in performance to the 2MB cache of the smaller disk. While the 60GB system drive portion can be made redundant across bot

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-04 Thread Warren Togami
On Wed, 2003-12-03 at 23:38, Thomas Ryan Gordon Sr wrote: > >> We should get another 60GB drive to mirror the other 60GB drive. > >> Preferably of the same model so they both run with similar speed and > >> access times. The exact model is $99 at local CompUSA, but I'm looking > >> for better deal

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-03 Thread Thomas Ryan Gordon Sr
R.Scott Belford wrote: On Wednesday, December 3, 2003, at 11:48 AM, Warren Togami wrote: We should get another 60GB drive to mirror the other 60GB drive. Preferably of the same model so they both run with similar speed and access times. The exact model is $99 at local CompUSA, but I'm lookin

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-03 Thread R.Scott Belford
On Wednesday, December 3, 2003, at 11:48 AM, Warren Togami wrote: We should get another 60GB drive to mirror the other 60GB drive. Preferably of the same model so they both run with similar speed and access times. The exact model is $99 at local CompUSA, but I'm looking for better deals elsewh

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-03 Thread Warren Togami
> > On Wednesday, December 3, 2003, at 07:45 AM, Warren Togami wrote: > >> I really want to launch server 3 with more than 240GB storage... but >> are >> you sure you are doing your math right? 120GB 2x mirrored is not >> 240GB... anyhow we'll figure it out. >> > > My sentence may have been mislea

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-03 Thread Vince Hoang
On Tue, Dec 02, 2003 at 08:31:44PM -1000, R. Scott Belford wrote: > Is priority one to replace the failed drive for this array? If > so, what size? I can order it tomorrow. I am assuming that it > needs to match the other 120gb drive I donated last year. One of the root disks died. I believe both

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-03 Thread R.Scott Belford
On Wednesday, December 3, 2003, at 07:45 AM, Warren Togami wrote: I really want to launch server 3 with more than 240GB storage... but are you sure you are doing your math right? 120GB 2x mirrored is not 240GB... anyhow we'll figure it out. My sentence may have been misleading. What I mean

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-03 Thread Warren Togami
On Tue, 2003-12-02 at 20:31, R. Scott Belford wrote: > > On Tuesday, December 2, 2003, at 07:44 PM, Warren Togami wrote: > > snip --- > > > Apparently one of the disks in the RAID1 array of videl.ics.hawaii.edu > > failed during November. I am hoping for donations to help pay for the > > replac

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-02 Thread Hawaii Linux Institute
Warren- I'll donate the lunch money intended for celebrating your finishing your finals to help this crisis. I am only interested in desktop projects which are closely tied to local causes. My own limited funds will have to be saved for those activities. Don't we wish that Chris Hemeter wer

Re: [luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-02 Thread R. Scott Belford
On Tuesday, December 2, 2003, at 07:44 PM, Warren Togami wrote: snip --- Apparently one of the disks in the RAID1 array of videl.ics.hawaii.edu failed during November. I am hoping for donations to help pay for the replacement disk and other upcoming server upgrades that are needed. Is prio

[luau] videl.ics.hawaii.edu disk failure - Your Help Needed

2003-12-02 Thread Warren Togami
Nov 9 13:11:23 videl kernel: hdc: dma_intr: status=0x51 { DriveReady SeekComplete Error } Nov 9 13:11:23 videl kernel: hdc: dma_intr: error=0x40 { UncorrectableError }, LBAsect=53035364, sector=53035232 Nov 9 13:11:23 videl kernel: end_request: I/O error, dev 16:01 (hdc), sector 53035232 Nov 9