How to Show Voltage Constraints and Branch Flow Constraints

2016-01-04 Thread Alanazi, Falah
Dear Sir, I would like to know how I can show the voltage constraints and the branch flow constraints when I run OPF. When I used the matpower cases both constraints showes up but when I used the WECC data they do not show up. I tried to use mpopt = mpoption('ENFORCE_Q_LIMS',0,'VERBOSE',3); m

Re: How to get cost parameters of generators

2016-01-04 Thread Ray Zimmerman
See Table B-4 in the User’s Manual for details of the gencost format. Column COST is the first column of the cost coefficients, which then appear in order in subsequent columns. E.g. The quadratic cost function, a*Pg^2 + b*Pg

Re: Running Available Transfer Capability (ATC-Power System)

2016-01-04 Thread Abhyankar, Shrirang G.
The number of input arguments to runpf() is incorrect. Please send the error log (output in the command window). Shri From: abde wahab naser mailto:abdewahab_na...@yahoo.com>> Reply-To: MATPOWER discussion forum mailto:matpowe...@list.cornell.edu>> Date: Monday, January 4, 2016 at 5:11 AM To: