RE: [NMusers] Negative concentration from simulation

2020-06-02 Thread Ken Kowalski
. Best, Ken -Original Message- From: owner-nmus...@globomaxnm.com [mailto:owner-nmus...@globomaxnm.com] On Behalf Of Nick Holford Sent: Tuesday, June 2, 2020 3:46 PM To: nmusers@globomaxnm.com Subject: RE: [NMusers] Negative concentration from simulation Hi Nyein, For drug

RE: [NMusers] Negative concentration from simulation

2020-06-02 Thread Zhang, Liping [JRDUS]
--- From: owner-nmus...@globomaxnm.com On Behalf Of Bill Denney Sent: Tuesday, June 2, 2020 2:30 PM To: Nyein Hsu Maung ; nmusers@globomaxnm.com Subject: [EXTERNAL] RE: [NMusers] Negative concentration from simulation Hi Nyein, Negative concentrations can be expected from simulations if the model include

Re: [NMusers] Negative concentration from simulation

2020-06-02 Thread Leonid Gibiansky
2020 8:30 PM To: Nyein Hsu Maung ; nmusers@globomaxnm.com Subject: RE: [NMusers] Negative concentration from simulation Hi Nyein, Negative concentrations can be expected from simulations if the model includes additive residual error. I assume that you mean additive and proportional

RE: [NMusers] Negative concentration from simulation

2020-06-02 Thread Zhang, Liping [JRDUS]
Of Bill Denney Sent: Tuesday, June 2, 2020 2:30 PM To: Nyein Hsu Maung ; nmusers@globomaxnm.com Subject: [EXTERNAL] RE: [NMusers] Negative concentration from simulation Hi Nyein, Negative concentrations can be expected from simulations if the model includes additive residual error. I assume

RE: [NMusers] Negative concentration from simulation

2020-06-02 Thread Nick Holford
the question, answer the question, attempt all questions -Original Message- From: owner-nmus...@globomaxnm.com On Behalf Of Bill Denney Sent: Tuesday, 2 June 2020 8:30 PM To: Nyein Hsu Maung ; nmusers@globomaxnm.com Subject: RE: [NMusers] Negative concentration from simulation Hi Nyei

RE: [NMusers] Negative concentration from simulation

2020-06-02 Thread Bill Denney
Hi Nyein, Negative concentrations can be expected from simulations if the model includes additive residual error. I assume that you mean additive and proportional error when you say "combined error model". If the error structure does not include additive error, then we'd need to know more. How

Re: [NMusers] Negative concentration from simulation

2020-06-02 Thread Leonid Gibiansky
you can treat it as any other value below quantification limit, and either comment it out (if you do this with other BQLs) or use it (same as other BQLs) Leonid On 6/2/2020 2:13 PM, Nyein Hsu Maung wrote: Dear NONMEM users, I tried to simulate a new dataset by using a previously published