Hi Ian,
I agree for general use archetypes, like the ones published on the CKM, this
may constraint more that is needed. But for us that build systems things like
these help us building spec-compliant archetypes to test our systems. With this
functionality in particular I need to test an UI that can show a form for each
action_archetype_id on the activity to record the correspondent action. I know
I can edit the ADL by hand, but that's a practice I try to avoid since it's
error prone.
This AE constraint (and others, e.g. couldn't create COMPOSITION archetypes
without slots i.e. the complete structure defined on the same archetype, or the
imposibility of add constraints to ISM_TRANSITION.transition) makes testing a
little difficult for us (of course these are drops in a sea of things to test
on an openEHR system).
Just thinking out loud, if such functionalities could be enabled in the AE, but
you're affraid that clinical modelers start to use the AE in a wrong way, maybe
a developers version of the AE could help here. What do you think?
--
Kind regards,
Ing. Pablo Pazos Guti?rrez
LinkedIn: http://uy.linkedin.com/in/pablopazosgutierrez
Blog: http://informatica-medica.blogspot.com/
Twitter: http://twitter.com/ppazos
From: ian.mcnic...@oceaninformatics.com
Date: Sun, 6 Jan 2013 14:33:41 +0100
Subject: Re: Improvement to specify more than one archetype on
ACTIVITY.arction_archetype_id [Archetype Editor]
To: openehr-technical at lists.openehr.org
Hi Pablo,
This seems sensible but, to be honest, I have never used this constraint
feature in any real-world applications. My experience has been to leave most of
these options open as it can be very difficult to predict appropriate future
matching archetypes.
Ian
On 5 January 2013 20:09, pablo pazos pazospablo at hotmail.com wrote:
Hi all,
When editing an INSTRUCTION archetype, setting the action_archetype_id
attribute of an ACTIVITY, the AE only gives the possibility of selecting one
archetype, but this should support more than one archetype using regexes as
said on the specs (ehr_im.pdf setion 8.3.7).
A solution could be to support the selection of more than one action archetype
(using the [...] button, see screen capture here:
https://plus.google.com/109540968085207927247/posts/f33Hs2rHoto) and creating a
regex from the selected archetypes like archid1|archid2|archid3
What do you think?
--
Kind regards,
Ing. Pablo Pazos Guti?rrez
LinkedIn: http://uy.linkedin.com/in/pablopazosgutierrez
Blog: http://informatica-medica.blogspot.com/
Twitter: http://twitter.com/ppazos
___
openEHR-technical mailing list
openEHR-technical at lists.openehr.org
http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org
--
Dr Ian McNicoll
office +44 (0)1536 414 994
fax +44 (0)1536 516317
mobile +44 (0)775 209 7859
skype ianmcnicoll
ian.mcnicoll at oceaninformatics.com
Clinical Modelling Consultant, Ocean Informatics, UK
Director openEHR Foundation www.openehr.org/knowledge
Honorary Senior Research Associate, CHIME, UCL
SCIMP Working Group, NHS Scotland
BCS Primary Health Care www.phcsg.org
___
openEHR-technical mailing list
openEHR-technical at lists.openehr.org
http://lists.openehr.org/mailman/listinfo/openehr-technical_lists.openehr.org
-- next part --
An HTML attachment was scrubbed...
URL:
http://lists.openehr.org/pipermail/openehr-technical_lists.openehr.org/attachments/20130106/05e366d3/attachment-0001.html