Re: Orion EJB 2.0 final

2002-03-29 Thread Robert Krüger
my advice is, don't rely on official tags like stable or unstable. download each version and do your testing with your application(s). during the past 2 years of working with orion sometimes the more serious bugs were in stable sometimes in unstable versions. just my 2c On Thursday 28

Memory leak with linux jdk1.4 - orion 1.5.4

2002-03-10 Thread Robert Krüger
hi, I'm experiencing serious problems with a memory leak that causes orion to consume more memory with each application restart/redeployment with the combination jdk1.4 (linux) - orion 1.5.4. with jdk 1.3 memory consumption remains constant after a while. even calling System.gc() explicitly

pitfalls migrating an app from orion to wls

2002-03-05 Thread Robert Krüger
Hi, just wanted to ask the list if anyone has migrated a compley app from orion to weblogic. we have a customer who wants us to port an app we developed for them from orion to weblogic (corporate policy). so far we have identified security (we have used orion security APIs) and cmp (we use

Re: pitfalls migrating an app from orion to wls

2002-03-05 Thread Robert Krüger
In the meantime, I just wanted to offer that I work for a company that develops what we call Portal Lifecycle Management tools (read application lifecycle for the web) on the J2EE platform. We currently support both Orion 1.5.x and WebLogic 6.1 (we require EJB 2.0 compliance), meaning we

Re: OC4J and Oracle 9i AS product version mappings

2001-09-14 Thread Robert Krüger
kuassi, does this mean you also fork the development for the J2EE core, i.e. bugfixes made there will not make it back to the ironflare orion development? hope you don't have to give away classified information to answer this question. regards, robert On Friday 14 September 2001 19:28,

Re: SMP/Linux/Hotspot/Orion problem.

2001-08-22 Thread Robert Krüger
Which jdk/kernel/glibc are you using? We have two production systems running a similar setup without any serious problems. Regards, Robert On Tuesday 21 August 2001 22:35, you wrote: Did anyone find a real solution to this problem? I have 2 smp linux boxes that running -classic mode

deployment question

2000-05-12 Thread Robert Krüger
-track here. thanks for any hints/comments, robert (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

Re: Problem with orion-ejb-jar.xml

2000-05-10 Thread Robert Krüger
s better... yours Christian Tellefsen Telenor Mobil AS - Planavdelingen (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

it's there (ibm linux jdk1.3)

2000-05-03 Thread Robert Krüger
might be of interest to some of you http://www.alphaworks.ibm.com/tech/linuxjdk (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

RE: Datatype size restrictions

2000-04-14 Thread Robert Krüger
Grey Interactive Paris (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

RE: Datatype size restrictions

2000-04-14 Thread Robert Krüger
Grey Interactive Paris (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

RE: Datatype size restrictions

2000-04-14 Thread Robert Krüger
in run time? I remember seeing a javaworld article a while back, but that was for older 1.1 versions of JDKs. Barry (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED

RE: Datatype size restrictions

2000-04-14 Thread Robert Krüger
in run time? I remember seeing a javaworld article a while back, but that was for older 1.1 versions of JDKs. Barry (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED

Re: AW: Unneeded calls to ejbStore

2000-04-11 Thread Robert Krüger
A #IMPLIED ^ isolation CDATA #IMPLIED location CDATA #IMPLIED max-tx-retries CDATA #IMPLIED name CDATA #IMPLIED table CDATA #IMPLIED validity-timeout CDATA #IMPLIED wrapper CDATA #IMPLIED Jens Stutte regards, robert (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechn

Fwd: Re: Orion on Linux

2000-04-08 Thread Robert Krüger
Date: Sat, 08 Apr 2000 16:46:29 +0200 To: [EMAIL PROTECTED] From: Robert Krüger [EMAIL PROTECTED] Subject: Re: Orion on Linux At 08:01 08.04.00 , you wrote: I haven't tried this, so who knows what might break, but you could write a stub servlet that you set to load on startup and have

RE: Is CMP is useless?

2000-04-04 Thread Robert Krüger
with the session bean which has SQL in it. I suppose that the bean's environment can be used to hold the specific SQL, with parameter replacements, however, this seems out of place with the CMP model. (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79

mod_rewrite equivalent for orion

2000-03-31 Thread Robert Krüger
(-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

principals

2000-03-23 Thread Robert Krüger
it? thanks, robert (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

Re: Alias

2000-03-19 Thread Robert Krüger
. http://www.windscape.comhttp://www.windscape.com (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

RE: Using Orion in an ASP scenario

2000-03-04 Thread Robert Krüger
. Thanks in advance, Gary Albers [EMAIL PROTECTED] (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

Fwd: Re: classloader problem

2000-02-08 Thread Robert Krüger
: writeObject only needs to know that the Object is of Serializable type (which they all are), readObject needs to call a constructor and therefor needs to have access to the class. is it something like that? any recommended reading on the topic? thanks, robert My 2 cents, Luke Robert Krüger

Re: Re: classloader problem

2000-02-08 Thread Robert Krüger
you think? thanks, robert (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

Re: deployment performance

2000-01-23 Thread Robert Krüger
e possible to significantly reduce deployment time for large projects. robert Noah Nordrum Hyperride Technologies (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], w

deployment performance

2000-01-22 Thread Robert Krüger
redeployed too including the code generation. this takes ages if your application has lots of ejbs and makes develoment quite slow. thanks, robert (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151

another pre-release?

2000-01-17 Thread Robert Krüger
)? thanks, robert (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de

Re: EJB w/ different DB's

2000-01-05 Thread Robert Krüger
hat effect) -- (-) Robert Krüger (-) SIGNAL 7 Gesellschaft für Informationstechnologie mbH (-) Brüder-Knauß-Str. 79 - 64285 Darmstadt, (-) Tel: 06151 665401, Fax: 06151 665373 (-) [EMAIL PROTECTED], www.signal7.de