ok
Ben Pfaff
2017/08/03 04:38
收件人:wang.qia...@zte.com.cn,
抄送: d...@openvswitch.org
主题: Re: [ovs-dev] [PATCH 1/2] ovn-controller: fix vlan_trunk
bug
On Fri, Jul 14, 2017 at 10:24:17AM +0800, wang.qia...@zte.com.cn wrote:
> The bug
switch.
The ovn-controller will make the relation between the logical_switch_port
and logica_mirror_switch_port.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/binding.c| 11 +-
ovn/controller/ovn-controller.c | 4 +-
ovn/controller/physical.c | 125
; function to some sub-function by the port type.
>
> Change-Id: I86a408e97e6d6211f3695cf42fc5b858352ac7ff
> Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
Thank you for the contribution.
This patch is word-wrapped and cannot be applied. Can you re-post it,
please? "git
The function of consider_port_binding is redundant. This patch divide the
function to some sub-function by the port type.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/physical.c | 816
+++---
1 file changed, 482 inse
The function of consider_port_binding is redundant. This patch split the
function to some sub-function by the port type.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/physical.c | 816
+++---
1 file changed, 482 inse
"taas". port with type "mirror" is used as inport for monitor flow in
> logica_mirror_switch, and port with type "taas" is used as outport for
> monitor flow in logica_mirror_switch.
>
> The ovn-controller will make the relation between the
logical_
The function of consider_port_binding is redundant. This patch divide the
function to some sub-function by the port type.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/physical.c | 834
++
1 file changed, 481 inse
The function of consider_port_binding is redundant. This patch divide the
function to some sub-function by the port type.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/physical.c | 816
+++---
1 file changed, 482 inse
ype "mirror" is used as inport for monitor
flow in logica_switch, and port with type "taas" is used as outport for
monitor flow in logica_switch.
The ovn-controller will make the relations of the ports in tap_service and
tap_flow to mirror port and taas port.
Signed-off
The bug description is as follow:
Neutron configure a trunk-sub port. The parent-port and sub-port located
in different network. there is a vm attached to parent port. And no vm
attached to the network of sub-port in the same chassis. In this
situation, the ovn-controller can not get the
The bug description is as follow:
Neutron configure a trunk-sub port. The parent-port and sub-port located
in different network. there is a vm attached to parent port. And no vm
attached to the network of sub-port in the same chassis. In this
situation, the ovn-controller can not get the
Localnet port is not an endpoint, and have no security requirements
to use localnet port at present. So, for performance consideration, we
could do not use ct for localnet port.
The more specific discussion can be found from
https://mail.openvswitch.org/pipermail/ovs-dev/2017-July/335048.html
The bug description is as follow:
Neutron configure a trunk-sub port. The parent-port and sub-port located
in different network. there is a vm attached to parent port. And no vm
attached to the network of sub-port in the same chassis. In this
situation, the ovn-controller can not get the
Hi Han
Thanks for the reiew job.
I will revise the commit message in new patch.
Qianyu
Han Zhou
2017/07/07 02:15
收件人:Mickey Spiegel ,
抄送: wang.qia...@zte.com.cn, ovs dev ,
xurong00037997
Hi Mickey,
Thanks for your review.
If we could do some modifications to avoid the north/south problem you
mentioned? Like as follow:
When packets send to the localnet-port, if the MAC is router-port MAC, we
change the router-port MAC to HV physical NIC MAC. And in gateway node, we
make the
Ok, I will make a new version which have no mirror switch. This may need
some days.
Thanks
Gao Zhenyu
2017/08/07 22:34
收件人:Ben Pfaff ,
抄送: wang.qia...@zte.com.cn, ovs dev ,
zhou.huij...@zte.com.cn,
Hi Zhenyu, Ben and Russell,
Thanks for your review.
I think function of taas is independent, and have no influence with
logical switch. Similar to logcial switch and logical router, I think
independent function should use independent pipeline.
Here, is there some constraints or problems to add
The function of consider_port_binding is redundant. This patch divide the
function to some sub-function by the port type.
Change-Id: I86a408e97e6d6211f3695cf42fc5b858352ac7ff
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/physical.c
Not add new logical_mirror_switch, just use logical_switch of course can
capture the use case. But logical_switch pipeline is complex for flow
monitor. Flow monitor should ignore some tables such as port_security, lb
and so on. And also should consider normal function for normal ports. I
think
If we do not add a new type of switch, we should write flag to a reg to
indicate the matched packets which are cloned to monitor.
This reg should add to all the pipeline stages of logical switch(both
ingress and egress) to distinguish from normal flow. Is this right for
Russell's point?
If we
t.
These assumptions may not hold going forward. In fact I refer to two
different patches below that are currently under review, that break your
assumptions.
On Fri, May 5, 2017 at 7:18 PM, <xu.r...@zte.com.cn> wrote:
> Hi,Russell
>
> We think vxlan is the most commonly used tunne
The current qos function is used for geneve
tunnel to control the traffic out the ovs. And have no to-port qos
control.
This patch do the modification as follow
1. change the qos configuration with direction to consistent with neutron
qos rule. Add qos_ingress_max_rate, qos_ingress_burst,
Hi Han Zhou,
> If using localnet, it should rely on physical network (L2 and L3) to
reach the destination, not overlay, so adding the logical router here
doesn't make sense here
Why ovn have this limit for physical network? Does this mean that vlan
network can not use the l3 function of ovn?
There are two computer node, each have one vm. And the two vms in
indifferent vlan networks. The ping between the vms is not success.
The reason is that, acl of to-localnet port or from-localnet port is
signed to contrack. So the pair of icmp request and reply have different
zone id in one ovs
There are two computer node, each have one vm. And the two vms in
indifferent vlan networks. The ping between the vms is not success.
The reason is that, acl of to-localnet port or from-localnet port is
signed to contrack. So the pair of icmp request and reply have different
zone id in one ovs
Thanks for you rapidly reply.
We think localnet port never be the real destination port of vm instance.
Like patch port of route, localnet port just used for interim.
And nouse of ct to localnet will not cause the bypass of firewall. Because
of the real destination port of vm1 or vm2 have
Hi Russell, I am sorry for the late reply.
The route not bound to a chassis, and have no redirect-chassis. The dumped
northbound db is as follow.
Ip addresses of 100.0.0.148 and 200.0.0.2 locate on different chassis. The
ping between them is not success before this patch.
[root@tecs159 ~]#
We want to use ovn in the scenary that ovs-computer node and sriov
computer node all managed by openstack.
However, in our analysis that ovn-controller-vtep could only be used to
forwards traffic between networks managed by openstack and physical
network openstack not managed.
Do we
rk openstack,ovn should better consider it.
>
> As my workmate wang qianyu said,we would consider computer node connect
> with existing hardware switches which associates with SR-IOV as VTEP.
>
> After discussion, we feel that as long as the following changes for
vxlan
> tunnel in the
router is not external to OVN
Russell Bryant
2017/06/05 20:12
收件人:wang.qia...@zte.com.cn,
抄送: Ben Pfaff , ovs dev ,
zhou.huij...@zte.com.cn, xurong00037997
主题: Re: [ovs-dev] [PATCH
ps://github.com/openstack/tap-as-a-service/blob/master/doc/source/presentations.rst
>
>
> > , and the api reference could be found from
> >
>
> *
https://github.com/openstack/tap-as-a-service/blob/master/API_REFERENCE.rst*
> <
https://github.com/openstack/tap-as-a-servi
Hi everyone,
Whether we could add a port property to logical flow? port property have
value of "normal" or logical port name. If the port property is "normal"
means this logical flow should be allocated to all HVs, if port property
is a name of logical_port, means this logical flow is related
How to configure multipath_port in static_route? I think the the multipath
can be figured out from exist data of static_route, may not need to add
this multipath_port column.
And I think we should add a status column to indicate the nexthop state.
When some of nexthop in multipath is down, ovn
e ovn-controller will make the relations of the ports in tap_service and
tap_flow to mirror port and taas port.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/controller/binding.c| 3 +
ovn/controller/ovn-controller.c | 2 +
ovn/controller/physical.c | 168 +++
op->sb->gateway_chassis[0]->chassis may null in some special cases, need
to add a check to avoid segment fault.
Signed-off-by: wang qianyu <wang.qia...@zte.com.cn>
---
ovn/northd/ovn-northd.c | 6 --
1 file changed, 4 insertions(+), 2 deletions(-)
diff --git a/ovn/northd/ovn
>From 80260a2950f10544e307d6f20cb1cfe8c9bb885f Mon Sep 17 00:00:00 2001
From: wang qianyu <wang.qia...@zte.com.cn>
Date: Thu, 21 Sep 2017 18:05:16 +0800
Subject: [PATCH] ovn: reduce logical flow applied to ovn-controller
Add a logical_port column in Logical_Flow table. If logical flow
I configure 5 networks, every network have about 80 ports, the total ports
is 400, all in same security group.
When I bind some port on HVs, the ovn-controller is always running with
100% cpu, and the total openflow table entities in ovs is more than
300,000. Most of the entities is table 52,
I agree with Han Zhou, This patch can reduce the flow to vswitchd, but
can not reduce the flow calculation of ovn-controller. It may be better to
move the check for
local_lport_ids before the parse happens. Add a lport column in logical
flow may be more efficient.
Thanks.
Han Zhou
lob/master/API_REFERENCE.rst
>
> To support taas function, this patch add two type of logica_switch_port,
> "mirror" and "taas". port with type "mirror" is used as inport for
monitor
> flow in logica_switch, and port with type "taas" is used as o
rst*
> <
https://github.com/openstack/tap-as-a-service/blob/master/doc/source/presentations.rst
>
>
> > , and the api reference could be found from
> >
>
> *
https://github.com/openstack/tap-as-a-service/blob/master/API_REFERENCE.rst*
> <
https://github.com/openstack/ta
"mirror" is used as inport for
monitor
> flow in logica_switch, and port with type "taas" is used as outport for
> monitor flow in logica_switch.
>
> The ovn-controller will make the relations of the ports in tap_service
and
> tap_flow to mirror port and taas port.
&g
flow in logica_switch, and port with type "taas" is used as outport for
> monitor flow in logica_switch.
>
> The ovn-controller will make the relations of the ports in tap_service
and
> tap_flow to mirror port and taas port.
>
> Signed-off-by: wang qianyu <wang.qia...@z
Hi everyone
Ovn-controller-vtep is the link of logical switch and pysical switch.
Whether we should deploy the Ovn-controller-vtep and vtep db with HA?
Thanks.
___
dev mailing list
d...@openvswitch.org
43 matches