Re: [Owfs-developers] Release 2.8p10

2011-09-04 Thread Paul Alfille
Do you have a make or schematic or datasheet for your humidity sensor? Paul Alfille On Sun, Sep 4, 2011 at 2:28 PM, Miska Sulander wrote: > Paul Alfille gmail.com> writes: > > > The humidity sensor as first published in "Sensors" magazine by Dan > > Awtrey used the HIH-3600 sensor and the VDD

Re: [Owfs-developers] Release 2.8p10

2011-09-04 Thread Miska Sulander
Paul Alfille gmail.com> writes: > The humidity sensor as first published in "Sensors" magazine by Dan > Awtrey used the HIH-3600 sensor and the VDD and VAD pins of the > DS2438. > > See http://www.elin.ru/files/pdf/1-Wire/humsensor.pdf -- it's nicely written. > > In my naivety I created a humid

Re: [Owfs-developers] Release 2.8p10

2011-06-21 Thread Paul Alfille
I did update the DS2438 man page, but haven't posted it to the web site. The DATANAB/reset is write-only yes-no (0 or 1). If written with a true (1) value, the calibration constants will be reread and the offset and current sensing reset to the proper state for humidity. This is done automatical

Re: [Owfs-developers] Release 2.8p10

2011-06-21 Thread Matthias Lemke
Paul Alfille schrieb: > Wonderful. > HIH3600/humidity > HIH4000/humidity > HTM1735/humidity > and now > DATANAB/humidity > > Because the DATANAB identifies itself, I can have the main humidity > point to DATANAB/humidity if it's a DATANAB design, and > HIH3600/humidity otherwise. > > Can you te

Re: [Owfs-developers] Release 2.8p10

2011-06-21 Thread Paul Alfille
Wonderful. The humidity sensor as first published in "Sensors" magazine by Dan Awtrey used the HIH-3600 sensor and the VDD and VAD pins of the DS2438. See http://www.elin.ru/files/pdf/1-Wire/humsensor.pdf -- it's nicely written. In my naivety I created a humidity file off the main DS2438 directo

Re: [Owfs-developers] Release 2.8p10

2011-06-21 Thread Matthias Lemke
Paul Alfille schrieb: > A minor release, mainly to get the Datanab humidity support out there. > > New release 2.8p10 > > 1. Support for the DataNAB humidity sensor. > 2. Don't cache empty directories > > The DATNAB humidity sensor uses the familiar HIH-4000 sensor and the > DS2438 like the ot