Re: [Powernet] MSA Iodine cartridges

2019-02-08 Thread Benfield, Eddie via Powernet
Per the literature the last time I read it that you could not take any protection factor for the cartridge against iodine. That may have changed since I read the literature and that was about 10 years ago. Sent from my iPad > On Feb 8, 2019, at 2:32 PM, Sandy Voss via Powernet > wrote: > >

Re: [Powernet] MSA Iodine cartridges

2019-02-08 Thread Sandy Voss via Powernet
Hi Sue I found them on www.coopersafety.com what efficiency do you get for iodine with this cartridge ? I am teaching an NRRPT exam prep class at Grand Junction and that is one of our questions. thanks Tom On Fri, February 8, 2019 7:40 am, Ziegler, Susanne E. via Powernet wrote: > We

[Powernet] MSA Iodine cartridges

2019-02-08 Thread Ziegler, Susanne E. via Powernet
We can’t seem to buy MSA GMI-P100 cartridges. Is anyone else having this problem. They are the iodine cartridges for the Ultratwin. sue Sue Ziegler PSEG Nuclear LLC Nuclear Technical Supervisor 856-339-5143 856-378-9425 Gadugi-working together for the good of all

Re: [Powernet] [EXTERNAL] Industry pulse on alpha instrument used to counts smears for alpha in the field

2019-02-08 Thread Rolph, James Thomas Jr via Powernet
Our procedural guidance requires better than 20 dpm within TVA. We currently use the Ludlum Model 12 with scaler option and a 43-92 detector. We are finding that as these instruments age we are not able to achieve the background and efficiency limits that permit us to use 2 minute counting. So

Re: [Powernet] [EXTERNAL] Industry pulse on alpha instrument used to counts smears for alpha in the field

2019-02-08 Thread Ziegler, Susanne E. via Powernet
What are the MDAs for everyone’s field alpha meters? Sue Sue Ziegler PSEG Nuclear LLC Nuclear Technical Supervisor 856-339-5143 856-378-9425 Gadugi-working together for the good of all [https://www.pseg.com/images/global/email/PSEG_emailsignature_PSEGw-tag_version2.png]