See the St. Lucie response below ...
1. A flow chart is used to drive the method to perform neutron monitoring
of personnel. The process evaluates whether the work involves containment
entry, ISFSI, a neutron source, or in areas outside the containment (such as by
the escape hatch), et
North Anna-
1.)Primarily SRD's however we will back that up with stay times and a REM
ball in case we get an anomaly with the SRD which has happened.
2.)No specific criteria other than what's stated above.
3.)No
4.)Yes we have an AmBe source and we track exposure when using tha
1. Primarily neutron SRDs
2. If area hasn't been characterized for neutron SRD energy response,
preferred technique is timekeeping with REM500
3. No
4. Yes. We have one neutron source and we require neutron dosimetry and
neutron surveys when working with this source
5. Only accessi