Hi,
yes, as Marcel says, this is in the SMSQ/E level 3 (DV3) drivers
(dv3_dv3_buff_asm), so it applies mostly to WIN or FLP devices, but not,
e.g. to the ram device which doesn't use the level 3 drivers.
I'm not sure how the various device drivers for QL + floppy interface
handle this.
I'll
Jan Bredenbeek via Ql-Users wrote:
>> Hi Jan,
>>
>> On what machine?
>>
> It does occur on QPC2 too and appears to be connected to WIN-devices
> (doesn't occur on ram and dos, only win).
Yes, seems to be a hard-coded feature of the DV3 drivers.
Marcel
__
On Tue, 24 Mar 2020 at 06:59, Wolfgang Lenerz via Ql-Users <
ql-users@lists.q-v-d.com> wrote:
> Hi Jan,
>
> On what machine?
>
It does occur on QPC2 too and appears to be connected to WIN-devices
(doesn't occur on ram and dos, only win).
Jan
--
*Jan Bredenbeek* | Hilversum, NL | j...@bredenbee
Hi Jan,
On what machine?
Wolfgang
I recently discovered that the IOB.FLIN trap on SMSQ/E, when called to read
a line from a file, strips any CR from lines ending in CR/LF.
However, this seems to happen ONLY with files on the WINx device!
I've tried several versions of SMSQ/E, even ones as old a