|777666/','Al0100-1800');
#
Hope help
David
-Puvodní zpráva-
Od: Hugh Irvine [mailto:[EMAIL PROTECTED]]
Odesláno: 2. srpna 2002 6:47
Komu: Ali Malik
Kopie: [EMAIL PROTECTED]
Predmet: Re: (RADIATOR) Caller ID settings
Hello Ali -
1. Radiator can use one or the other of Called
Dear All:
Finally Iam able to integrate the Quidway 8010
refiner with radius. Now, i want to restrict CLI for dial-in users. I have
questions:
1. How Radiator will handle CLI,
2. How I can restrict user to connect only when its
coming from the defined number.
3. Can i define multiple
Hello Ali -
1. Radiator can use one or the other of Called-Station-Id and/or Calling-Station-Id
2. Your user definition would look like this:
someuser Password = x, Calling-Station-Id = nnn
.
3. You can define multiple numbers with regular expressions:
someuser Password = x,
Seriously, change the usernames and passwords. How do you know they
won't use them from another phone number? You are setting yourself up
for pain and suffering.
Just my $0.02
cheers
Mike McCauley wrote:
On Apr 15, 2:54pm, Richard Hawley wrote:
Subject: Re: (RADIATOR) Caller ID
On Mon, Feb 22, 1999 at 09:41:09PM +0200, Lutfi Yunusoglu wrote:
Hi,
We are using MaxTNT's and Radiator with Oracle8,
What should I put to check items for CLID Authentication.
Thanks
Lutfi
PS: I want to do this for some users.
You'd use Calling-Station-Id = "1234567" as a check