On 08/17/2018 01:08 PM, Petru Rațiu wrote:
On Fri, Aug 17, 2018 at 12:34 PM Alex 'CAVE' Cernat wrote:
Eu mai avusesem probleme similare cu raiduri hw cu discuri busite si tin
minte ca a trebuit sa-i dau $ceva ca sa se prinda ca am schimbat discul si
sa-l reinitializeze; speram ca se gaseste
On Fri, Aug 17, 2018 at 12:34 PM Alex 'CAVE' Cernat wrote:
> On 17-Aug-18 11:18 AM, Adrian Popa wrote:
> > logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode)
> >
> > physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive
> > Failure)
> > physicaldrive 1I:1:4
On 17-Aug-18 11:18 AM, Adrian Popa wrote:
> logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode)
>
> physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive
> Failure)
> physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)
> physicaldrive 2I:1:5 (port
On 08/17/2018 11:18 AM, Adrian Popa wrote:
Salut,
Am un server vechi HP cu un RAID5 cu un disk defect. L-am schimbat fizic cu
unul nou, dar array-ul nu vrea să se refacă. Am instalat hpacucli și pot să
văd starea array-ului și a discurilor:
logicaldrive 2 (1.4 TB, RAID 5, Interim
Salut,
Am un server vechi HP cu un RAID5 cu un disk defect. L-am schimbat fizic cu
unul nou, dar array-ul nu vrea să se refacă. Am instalat hpacucli și pot să
văd starea array-ului și a discurilor:
[root@Tassadar adrianp]# hpacucli
HP Array Configuration Utility CLI 9.20.9.0
Detecting