Re: [rlug] Rebuild RAID HP cu hpacucli

2018-08-17 Fir de Conversatie Adrian Minta
On 08/17/2018 01:08 PM, Petru Rațiu wrote: On Fri, Aug 17, 2018 at 12:34 PM Alex 'CAVE' Cernat wrote: Eu mai avusesem probleme similare cu raiduri hw cu discuri busite si tin minte ca a trebuit sa-i dau $ceva ca sa se prinda ca am schimbat discul si sa-l reinitializeze; speram ca se gaseste

Re: [rlug] Rebuild RAID HP cu hpacucli

2018-08-17 Fir de Conversatie Petru Rațiu
On Fri, Aug 17, 2018 at 12:34 PM Alex 'CAVE' Cernat wrote: > On 17-Aug-18 11:18 AM, Adrian Popa wrote: > > logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode) > > > > physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive > > Failure) > > physicaldrive 1I:1:4

Re: [rlug] Rebuild RAID HP cu hpacucli

2018-08-17 Fir de Conversatie Alex 'CAVE' Cernat
On 17-Aug-18 11:18 AM, Adrian Popa wrote: > logicaldrive 2 (1.4 TB, RAID 5, Interim Recovery Mode) > > physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, Predictive > Failure) > physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) > physicaldrive 2I:1:5 (port

Re: [rlug] Rebuild RAID HP cu hpacucli

2018-08-17 Fir de Conversatie Adrian Minta
On 08/17/2018 11:18 AM, Adrian Popa wrote: Salut, Am un server vechi HP cu un RAID5 cu un disk defect. L-am schimbat fizic cu unul nou, dar array-ul nu vrea să se refacă. Am instalat hpacucli și pot să văd starea array-ului și a discurilor: logicaldrive 2 (1.4 TB, RAID 5, Interim

[rlug] Rebuild RAID HP cu hpacucli

2018-08-17 Fir de Conversatie Adrian Popa
Salut, Am un server vechi HP cu un RAID5 cu un disk defect. L-am schimbat fizic cu unul nou, dar array-ul nu vrea să se refacă. Am instalat hpacucli și pot să văd starea array-ului și a discurilor: [root@Tassadar adrianp]# hpacucli HP Array Configuration Utility CLI 9.20.9.0 Detecting