I think this issue is occuring because I am running a bcache cache
device on a VROC IMSM 'fake raid' device. Once I followed Dimitri's
finalrd steps in post #14 (this is required), I also had to add the
following script '/lib/systemd/system-shutdown/bcache_stop'
Please make sure you run 'chmod +x
I find that the issue is resolved if I run "/usr/bin/finalrd" after I
boot so that the /run/initramfs directory is populated.
Do I need to run "/usr/bin/finalrd" on start (I see it runs on
shutdown)?
Do I need any "/etc/initramfs-tools" hooks or scripts?
--
You received this bug notification
It seems like the fix stopped working - On every reboot now, the IMSM
VROC raid drive is being resynced
Is this related to a bug that produces this error? I see this a few
times right before reboot
systemd shutdown [1] Failed to wait for process : protocol error
--
You received this bug
First reboot: IMSM/VROC RAID1 resynced (as you stated)
I waited for the RAID volume to become clean and then rebooted.
Second reboot: Raid did not resync and bcache volume successfully mounted!
Third reboot: Raid did not resync and bcache volume successfully mounted!
Thank you so much,
Anything special needed for bcache for finalrd?
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1608495
Title:
IMSM fakeraid handled by mdadm: unclean mounted volumes on
shutdown/reboot
To manage
thank you so much, Dimitri. I will test and confirm
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1608495
Title:
IMSM fakeraid handled by mdadm: unclean mounted volumes on
shutdown/reboot
To
I am having this issue using IMSM / VROC 6.2 on Ubuntu 18.04 LTS, Kernel
5.3.0-28, mdadm - v4.1-rc1 - 2018-03-22.
I am running a bcache cache device on one of the RAID 1 IMSM (VROC)
arrays. At the very minimum, every reboot the device needs to resync
(not shutting down clean).
What other
I am having this issue using IMSM / VROC 6.2 on Ubuntu 18.04 LTS, Kernel
5.3.0-28, mdadm - v4.1-rc1 - 2018-03-22.
I am running a bcache cache device on one of the RAID 1 IMSM (VROC)
arrays. At the very minimum, every reboot the device needs to resync
(not shutting down clean).
What other