Checking back in. Can we reference the user-defined custom config parms
passed in from ExecuteScript as *sys.argvs* in the python script being
executed by ExecuteScript?
On Fri, Feb 16, 2018 at 1:14 PM, James McMahon wrote:
> Good afternoon. I have a python script I would
Hi Kevin,
Noted and thank you very much.
Best Regards,
Nick
On 18 Feb 2018 21:29 +0700, Kevin Doran , wrote:
> Hi Nick,
>
> Just wanted to shoot you a quick note mentioning that this issue was resolved
> in NiFi 1.5.0 which was released in January. If/when you upgrade, be
Jim,
I don't think that's possible because I don't think the user-defined
properties are guaranteed to be in a particular order (insertion order
in the processor config dialog, e.g.), but someone please correct me
if I'm wrong. If true, then we wouldn't be able to have the
user-defined properties
Hi Nick,
Just wanted to shoot you a quick note mentioning that this issue was resolved
in NiFi 1.5.0 which was released in January. If/when you upgrade, be sure to
change your configuration from 120ms to 120s (or whatever time interval you
prefer to use, it will work correctly now). There