HI All
Scenario:
Master server HP-UX gbaheu17 B.11.00 U 9000/800
Media Server Linux gbahel25.gb.tntpost.com 2.4.21-20.ELsmp
Tape Library Storagetek using SN6000
A large portion of backups are written to disk mounted on the media server and
then disk staged at a later to tape . Along with
David
Do all the backups run at the same time (ie: 7:00pm) - Maybe they can be
staged? We used to run into 134 a long, long time ago, but since backups are
staggered through the night, they are long long gone!
Simon Weaver
Technical Support
Windows Domain Administrator
EADS Astrium
Tel:
Simon
Not extensively in my opinion , currently running :
Mater server
2 jobs active to tape ,
2 Q'ed ( spitting out 134's ) until either active job completes
Four drives available on master server , only two used , max jobs set correctly
on both storage unit, global attributes and client
Good call, its another way of doing it.
The exclude, include way seems to have worked, so if there are
performance hits ill look at doing it the script way.
Thanks
[EMAIL PROTECTED] wrote:
There will definitely be a performance hit. All wildcards are expensive but
that's the price you pay
Hi
In the properties for the Master Storage Unit, is it set to use Max
Concurrent Drives Used For Backups set to 4 correctly?
Although 4 drives are available, is it set for 4 to be used in the
properties?
Also, what is set for the Maximum Multiplexing per drive set at??
Thanks
Simon Weaver
Simon,
I can only tell you what we do
W2k master media plus a w2k3 media server (5.1mp4), everything attached
to an ADIC scaler 2000 with 10 drives, SSO shared with master media and
media servers.
The master server is set to use 3 Max Concurrent drives (which means our
master server will never
Mark
Must admit, never used bpschedreq before - Only had to stop using a media
server a few times due to maintenance, but even so, changing it in the
policy is going to be easier.
Simon Weaver
Technical Support
Windows Domain Administrator
EADS Astrium
Tel: 02392-708598
Email: [EMAIL
David,
Turn off max concurrent jobs, or set to higher number. Also select
allow multiple data streams in policy attributes in the schedule. In
Change storage unit, make sure you've selected maximum multiplexing per
drive to 5 or 6. You'll have to restart the services to get the changes
to work.
Thank you to all who replied to this thread. The media server is a SAN media
server so no policies will need to be changed.
The intent of this thread was to minimize the consequences of the
inter-relationships between all of the other media servers.
I want to minimize timeouts with SSO, and
Hi Bob,
I don't think you'll need to do anything, SSO will simply select one of the remaining hosts as the scan host and carry on as per normal. SSO is designed to be rebust WRT this
thanks Andy.
Bob Stump [EMAIL PROTECTED]
Sent by: [EMAIL PROTECTED]
14/03/2006 14:26
Hello,
My environment consists of NB 5.1 running on HP-UX 11.11 U 9000/800 and Storage
Tek L180 tape library. Right now the library has 140 slots and planning to
upgrade it to 180 slots.
I have scheduled a upgrade with our STK engineer tomorrow, was wondering if I
need to do anything on the
Im having a problem with a policy which backs up 4 drives on the server and
one of the drives it backed up 20 times last night. Both media and client
are 5.1. Any help would be appreciated.
Thanks
Frank
___
Veritas-bu maillist -
So far I havent seen even single positive reply, I
have gotten few very negatives.
Can someone from Veritas shed some light? My questions
are more from the implementation of VxSS in a
NetBackup 6.0MP1 environment:
1. Is it recommeneded to install Authentication Broker
+ Roor Broker on same
I believe just inventory and NBU should find the slots.
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
Pillapalem, Smitha
Sent: Tuesday, March 14, 2006 8:25 AM
To: veritas-bu@mailman.eng.auburn.edu
Subject: [Veritas-bu] Slot upgrade
Hello,
My
From what I have heard from Veritas, they recommend
that the VxSS and NOM server be one in the same.
--- mkiles [EMAIL PROTECTED] wrote:
So far I havent seen even single positive reply, I
have gotten few very negatives.
Can someone from Veritas shed some light? My
questions
are more
We are currently backing up a system with LTO gen 1 drives/media and trying to
recover using LTO gen 2 drives (LTO 1 drives are IBM and LTO 2 drives are HP).
We are using NBU 4.5 and when the LTO 1 tapes are loaded into the gen 2 drive,
the drives are downed. Any ideas what can be causing this
I am trying to verify if a failed backup used a particular
drive. Is there a way to do this? I can determine the tape and the storage
unit that the backup used, but not sure about the specific drive that was
used. This is important because I was trying to determine if the failed backup
To the best of my knowledge, you should not need to. Once the robot /
library is powered off and the new slots are installed, the robot will do
its own inventory.
Once that's completed, run an Inventory on the robot in Netbackup to make
sure it can see the slots.
No additional changes that I
Hi
I would still say that if you absolutely, positively do NOT need VXSS then
do not implement it!
Rocky is right, plan, plan and plan because it really really gives nothing
but headaches.
But I guess if setup from a clean install, and working correctly, it may be
problem free.
If the scenario