Re: [Veritas-vx] Q About 122058-11
01. Was the patch installed in single-user mode? 02. Did the patch complete installation? 03. Did you install patch 119254-06 or later revision as the special installation instructions said? 04. What does the /var/sadm/patch/122058/log indicate? -GGR On Thu, Oct 16, 2008 at 3:59 AM, Paul Liong [EMAIL PROTECTED] wrote: Hi All, Our system is a Sun Solairs 10 Box with VM 5.0 MP1. Recently, we have applied the latest VM patch 122058-11 into the system. However, when we try to reboot the box after the patch installation, the system doesn't reboot after 'init 6' is invoked. So, do anyone know the reason why? Thanks in advance. Regards Paul ___ Veritas-vx maillist - Veritas-vx@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-vx ___ Veritas-vx maillist - Veritas-vx@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-vx
[Veritas-vx] Fwd: vxunreloc for veritas 2.4
Doug, From an address without the confidentiality trailer. Hello, I have a question for the list regarding vxunreloc or something similar for veritas volume manager 2.4. I have a volume as shown below that is mirrored on 2 arrays c0 and c2, with 1 plex on each array. I had a failed disk, disk24 (c2t15)and hot relocation replaced it with d012 shown below as c0t1d2. This is not good because c0t1d2 is on the on the wrong array. So the plex is not properly mirrored since now if the c0 array goes down, the volume will have no valid plex. I replaced the failed disk which was disk24 (c2t1d5) and veritas now sees it again. I do not believe there is a vxunreloc available for vxvm 2.4. So my question is how can I relocate the stripe now contained on d012 (c0t1d2) back to disk24 (c2t1d5) so I can have all the stripes for this plex on the same array? Also do I have to take the volume offline to do this first? I would not think so since the plex on c0 will not be modified. Thank you James v tooldwnldfsgenENABLED ACTIVE 7000 SELECT- pl tooldwnload-01 tooldwnld ENABLED ACTIVE 70713981 STRIPE4/32 RW sd disk29-01tooldwnload-01 disk29 017678493 0/0 c0t2d3 ENA sd disk30-01tooldwnload-01 disk30 017678493 1/0 c0t2d4 ENA sd disk42-01tooldwnload-01 disk42 017678493 2/0 c0t3d2 ENA sd disk43-01tooldwnload-01 disk43 017678493 3/0 c0t3d3 ENA pl tooldwnld-02 tooldwnldENABLED ACTIVE 70713981 STRIPE4/32 RW sd d211-01 tooldwnld-02 d211 017678493 0/0 c2t1d1 ENA sd disk35-01tooldwnld-02 disk35 017678493 1/0 c2t2d2 ENA sd d012-01 tooldwnld-02 d012 017678493 2/0 c0t1d2 ENA -- used to be disk 24, c2t1d5 sd disk37-01tooldwnld-02 disk37 017678493 3/0 c2t2d4 ENA ___ Veritas-vx maillist - Veritas-vx@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-vx
Re: [Veritas-vx] Fwd: vxunreloc for veritas 2.4
Hi James, not sure about 2.4, but 3.5 and above has option 14 in the vxdiskadm menu which sounds right up your alley. failing that, the vxassist move option might do the same. So, at a guess, something like: vxassist -g tooldwnld-dg move tooldwnld \!d012 disk24 (please dont use that command without further investigation and testing) It also looks like vxsd mv option can also move subdisks. That one looks simplier to understand than my vxassist command. I'd be more confortable with option 14 from vxdiskadm though. Hope this helps, Greg. From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of James Chavez Sent: Monday, 20 October 2008 8:47 AM To: veritas-vx@mailman.eng.auburn.edu Subject: [Veritas-vx] Fwd: vxunreloc for veritas 2.4 Doug, From an address without the confidentiality trailer. Hello, I have a question for the list regarding vxunreloc or something similar for veritas volume manager 2.4. I have a volume as shown below that is mirrored on 2 arrays c0 and c2, with 1 plex on each array. I had a failed disk, disk24 (c2t15)and hot relocation replaced it with d012 shown below as c0t1d2. This is not good because c0t1d2 is on the on the wrong array. So the plex is not properly mirrored since now if the c0 array goes down, the volume will have no valid plex. I replaced the failed disk which was disk24 (c2t1d5) and veritas now sees it again. I do not believe there is a vxunreloc available for vxvm 2.4. So my question is how can I relocate the stripe now contained on d012 (c0t1d2) back to disk24 (c2t1d5) so I can have all the stripes for this plex on the same array? Also do I have to take the volume offline to do this first? I would not think so since the plex on c0 will not be modified. Thank you James v tooldwnldfsgenENABLED ACTIVE 7000 SELECT- pl tooldwnload-01 tooldwnld ENABLED ACTIVE 70713981 STRIPE4/32 RW sd disk29-01tooldwnload-01 disk29 017678493 0/0 c0t2d3 ENA sd disk30-01tooldwnload-01 disk30 017678493 1/0 c0t2d4 ENA sd disk42-01tooldwnload-01 disk42 017678493 2/0 c0t3d2 ENA sd disk43-01tooldwnload-01 disk43 017678493 3/0 c0t3d3 ENA pl tooldwnld-02 tooldwnldENABLED ACTIVE 70713981 STRIPE4/32 RW sd d211-01 tooldwnld-02 d211 017678493 0/0 c2t1d1 ENA sd disk35-01tooldwnld-02 disk35 017678493 1/0 c2t2d2 ENA sd d012-01 tooldwnld-02 d012 017678493 2/0 c0t1d2 ENA -- used to be disk 24, c2t1d5 sd disk37-01tooldwnld-02 disk37 017678493 3/0 c2t2d4 ENA IMPORTANT: This email remains the property of the Australian Defence Organisation and is subject to the jurisdiction of section 70 of the CRIMES ACT 1914. If you have received this email in error, you are requested to contact the sender and delete the email. ___ Veritas-vx maillist - Veritas-vx@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-vx
Re: [Veritas-vx] Fwd: vxunreloc for veritas 2.4
following the top posting.. to use vxsd mv, you must first make the subdisk on the destination by hand using vxmake. something like vxmake -g tooldwnld-dg sd disk24-01 dm_name=disk24 dm_offset=0 len = 17678493 vxsd -o rm mv d012-01 disk24-01 (this last operation will take a long time) Check vxmake man pages for proper details on names and usage for vxmake. Robinson, Greg wrote: Hi James, not sure about 2.4, but 3.5 and above has option 14 in the vxdiskadm menu which sounds right up your alley. failing that, the vxassist move option might do the same. So, at a guess, something like: vxassist -g tooldwnld-dg move tooldwnld \!d012 disk24 (please dont use that command without further investigation and testing) It also looks like vxsd mv option can also move subdisks. That one looks simplier to understand than my vxassist command. I'd be more confortable with option 14 from vxdiskadm though. Hope this helps, Greg. *From:* [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] *On Behalf Of *James Chavez *Sent:* Monday, 20 October 2008 8:47 AM *To:* veritas-vx@mailman.eng.auburn.edu *Subject:* [Veritas-vx] Fwd: vxunreloc for veritas 2.4 Doug, From an address without the confidentiality trailer. Hello, I have a question for the list regarding vxunreloc or something similar for veritas volume manager 2.4. I have a volume as shown below that is mirrored on 2 arrays c0 and c2, with 1 plex on each array. I had a failed disk, disk24 (c2t15)and hot relocation replaced it with d012 shown below as c0t1d2. This is not good because c0t1d2 is on the on the wrong array. So the plex is not properly mirrored since now if the c0 array goes down, the volume will have no valid plex. I replaced the failed disk which was disk24 (c2t1d5) and veritas now sees it again. I do not believe there is a vxunreloc available for vxvm 2.4. So my question is how can I relocate the stripe now contained on d012 (c0t1d2) back to disk24 (c2t1d5) so I can have all the stripes for this plex on the same array? Also do I have to take the volume offline to do this first? I would not think so since the plex on c0 will not be modified. Thank you James v tooldwnldfsgenENABLED ACTIVE 7000 SELECT- pl tooldwnload-01 tooldwnld ENABLED ACTIVE 70713981 STRIPE4/32 RW sd disk29-01tooldwnload-01 disk29 017678493 0/0 c0t2d3 ENA sd disk30-01tooldwnload-01 disk30 017678493 1/0 c0t2d4 ENA sd disk42-01tooldwnload-01 disk42 017678493 2/0 c0t3d2 ENA sd disk43-01tooldwnload-01 disk43 017678493 3/0 c0t3d3 ENA pl tooldwnld-02 tooldwnldENABLED ACTIVE 70713981 STRIPE4/32 RW sd d211-01 tooldwnld-02 d211 017678493 0/0 c2t1d1 ENA sd disk35-01tooldwnld-02 disk35 017678493 1/0 c2t2d2 ENA sd d012-01 tooldwnld-02 d012 017678493 2/0 c0t1d2 ENA -- used to be disk 24, c2t1d5 sd disk37-01tooldwnld-02 disk37 017678493 3/0 c2t2d4 ENA ___ Veritas-vx maillist - Veritas-vx@mailman.eng.auburn.edu http://mailman.eng.auburn.edu/mailman/listinfo/veritas-vx