01. Was the patch installed in single-user mode?
02. Did the patch complete installation?
03. Did you install patch 119254-06 or later revision as the special
installation instructions said?
04. What does the /var/sadm/patch/122058/log indicate?
-GGR
On Thu, Oct 16, 2008 at 3:59 AM, Paul Liong
Doug, From an address without the confidentiality trailer.
Hello,
I have a question for the list regarding vxunreloc or something similar
for veritas volume manager 2.4.
I have a volume as shown below that is mirrored on 2 arrays c0 and c2,
with 1 plex on each array. I had a failed disk, disk24
Hi James,
not sure about 2.4, but 3.5 and above has option 14 in the vxdiskadm
menu which sounds right up your alley.
failing that, the vxassist move option might do the same.
So, at a guess, something like:
vxassist -g tooldwnld-dg move tooldwnld \!d012 disk24
(please dont use that
following the top posting..
to use vxsd mv, you must first make the subdisk on the destination by
hand using vxmake.
something like vxmake -g tooldwnld-dg sd disk24-01 dm_name=disk24
dm_offset=0 len = 17678493
vxsd -o rm mv d012-01 disk24-01
(this last operation will take a long time)
Check