Re: [WISPA] Bullet2 HP reverting to factory defaults!

2012-12-05 Thread Josh Luthman
Water in the line or a busted poe. New poe. Cut a slit at the low point of the cable. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Dec 5, 2012 5:40 PM, ~NGL~ n...@ngl.net wrote: ** I have had 2 Bullet2 HP reverting to factory defaults! 1

Re: [WISPA] Bullet2 HP reverting to factory defaults!

2012-12-05 Thread ~NGL~
Water could be correct, we have had about 5 inches of rain in the last week. I will check that out. Will cutting a slit in the cable solve the water problem? Thanx for the info! NGL From: Josh Luthman Sent: Wednesday, December 05, 2012 2:42 PM To: WISPA General List Subject: Re: [WISPA]

Re: [WISPA] Bullet2 HP reverting to factory defaults!

2012-12-05 Thread Justin Wilson
+1 From: Josh Luthman j...@imaginenetworksllc.com Reply-To: WISPA General List wireless@wispa.org Date: Wednesday, December 5, 2012 5:42 PM To: WISPA General List wireless@wispa.org Subject: Re: [WISPA] Bullet2 HP reverting to factory defaults! Water in the line or a busted poe. New

Re: [WISPA] Bullet2 HP reverting to factory defaults!

2012-12-05 Thread Josh Luthman
I've had it a bunch. Like 4 times now. The slit drains the water but each time I also disable reset in the config. I try to disable it everywhere. If only Air control worked... Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Dec 5, 2012 5:52