Thanks for all the responses on this. Upgrade worked a treat.
Was a better response than vendor support but to be fair we hadn’t logged one
with freeradius
--
Jason Cook
The University of Adelaide, AUSTRALIA 5005
Ph: +61 8 8313 4800
From: The EDUCAUSE Wireless Issues Constituent Group
My recommendations assume a baseline level of competence. The NEC requires
that all communications equipment be installed in accordance with the
manufacturer’s recommendations. Anybody who doesn’t know that much not only
shouldn’t design these systems, but they shouldn’t install or maintain
If you know what you’re doing, design the system appropriately. If not, get
help. Pretty simple.”
I would counter that statement with, “You don’t know what you don’t know.”
If you’ve never read the documentation for an outdoor-rated camera/AP, you
probably don’t know that you need to use
We started using these L-Com BT-CAT6-P1-HP Injector Kit with 48VDC @ 70 W Power
Supply to power our outdoor Aruba AP-175 APs. Just like Chuck, we are
installing them inside the buildings starting this year.
You’re correct, of course, that your approach reduces your institution’s
liability. That would be true of any decision faced by any employee of any
institution. It begs the question why universities hire their own subject
matter experts at all. Why not just have a huge staff to outsource