Ran the Loppback
Site 1 provided MSE of -42 and RSSI of -34
Site 2 provided a low RSSI (-71) and MSE of 0
From: > on behalf
of Jon Langeler >
Gino Villarini
8.7
From: > on behalf
of Jon Langeler >
Gino Villarini
President
Metro Office Park #18 Suite 304 Guaynabo, Puerto Rico 00968
Firmware version?
Jon Langeler
Michwave Technologies, Inc.
> On Jan 29, 2017, at 12:40 PM, Gino Villarini wrote:
>
> I have:
>
> Radio 1, Admin UP , Operational UP
> Radio 2, Admin UP , Operational Down
>
> Funny thing is, we used 1 script for alignment ( 5 mhz channel,
Could be a bad odu, trasmit power failing is somewhat common, we've had two ptp
820S fail in the past two years, different reasons. Submit a ticket. They'll
have you power cycle, replace all the cabling, try direct dc wire, replace the
power and then 4 months later you might get a new one on
I have:
Radio 1, Admin UP , Operational UP
Radio 2, Admin UP , Operational Down
Funny thing is, we used 1 script for alignment ( 5 mhz channel, low
modulation), Aligned, got target, changed script to bigger channelŠ
kaputt!
On 1/29/17, 11:50 AM, "wireless-boun...@wispa.org on behalf of Seth
On 1/29/17 9:46 AM, Gino Villarini wrote:
> Turned off adaptive power, no avail
>
> Using MRMC script of 260 mbps
>
> Nothing getting flagged in license page
If you were out of license the background goes yellow and it alerts you
every time you click on something. It's extremely obvious.
I only say that because if one side has a -34 and the other is -70 your within
the window for being at 0db transmit power on Site 1. If you are in an rf
conjested area the -0 MSE would make sense if your pcn target was -34.
Sent from my Verizon, Samsung Galaxy smartphone
Original
Dual pol antennas? Make sure you have the hollow or circular waveguide as
opposed to slotted. Not sure..
Jon Langeler
Michwave Technologies, Inc.
> On Jan 29, 2017, at 12:51 PM, Gino Villarini wrote:
>
> 8.7
>
> From: on behalf of Jon
On 1/29/17 11:42 AM, Christian Palecek wrote:
> Could be a bad odu, trasmit power failing is somewhat common, we've had
> two ptp 820S fail in the past two years, different reasons. Submit a
> ticket. They'll have you power cycle, replace all the cabling, try
> direct dc wire, replace the power
I don’t have that option on my GUI,
Quick Configuration?
From: > on behalf
of Jon Langeler >
Gino Villarini
President
Metro Office Park #18 Suite 304 Guaynabo, Puerto
On 1/29/17 2:38 AM, Gino Villarini wrote:
> This is what I have
>
>
Platform -> Manager -> Interface Manager
Check for admin up.
Did you check the stickers to make sure you didn't get shipped two of
the same unit instead of a high/low pair? I don't know if the UI would
let you configure the
11 matches