Glasgow G20 0SP
Email Disclaimer
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Bob Arnson
Sent: 07 September 2008 21:16
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] does running upgrade msi or patch msi still
require
.
-Original Message-
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Pally Sandher
Sent: Tuesday, September 09, 2008 5:54 AM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] does running upgrade msi or patch msi still require
additional command
Installer XML toolset.
Subject: Re: [WiX-users] does running upgrade msi or patch msi still require
additional command line switches?
In our installs, we don't utilize a patch wrapper.
Instead, we set the REINSTALL and REINSTALLMODES appropriately within our
installation(s)...
CustomAction Id
: [EMAIL PROTECTED] [EMAIL PROTECTED] On Behalf Of Robert O'Brien [EMAIL
PROTECTED]
Sent: Tuesday, September 09, 2008 1:19 PM
To: 'General discussion for Windows Installer XML toolset.'
Subject: Re: [WiX-users] does running upgrade msi or patch msi still require
additional command line switches
Sent: Friday, September 05, 2008 10:45 AM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] does running upgrade msi or patch msi still require
additional command line switches?
Robert O'Brien wrote:
Q1 - does running upgrade msi or patch msi still require
Robert O'Brien wrote:
q2 - do the same REINSTALLMODE switch settings apply when trying to use a
patch to carry out a minor or major upgrade?
Yes, though usually MSI picks the right values for you. Though patches
aren't generally double-click installable; you usually need to provide a
Robert O'Brien wrote:
Q1 - does running upgrade msi or patch msi still require additional command
line switches?
Minor upgrades must be applied with arguments. Major upgrades don't need
them.
Q2 - I seem to recall running into upgrade capable msi's and patch msp's that
I could simple
Q1 - does running upgrade msi or patch msi still require additional command
line switches?
In the WiX tutorial Lesson 4 Upgrades and modularization details it talks about
needing the use the following command line switches to run an upgrade msi
msiexec /i SampleUpgrade2.msi REINSTALL=ALL