Em 26-10-2012 17:42, Jeremy Evans escreveu:
On Friday, October 26, 2012 12:16:02 PM UTC-7, Rodrigo Rosenfeld Rosas wrote:

    Just to let you know, it seems a Monitor is reentrant if you want
    to take this path:

    http://japgolly.blogspot.com.br/2012/04/ruby-mutex-reentrancy.html
    <http://japgolly.blogspot.com.br/2012/04/ruby-mutex-reentrancy.html>


I'm aware of the difference, Mutex is being used on purpose for performance (Monitor is about 2.5x slower).

One other limitation with the current code is that it does the connection validation while holding the pool mutex, which means that no other threads can checkout a connection while this connection is being validated. That's very bad. I've modified things so the checking is done while not holding the mutex (in addition to precaching the SQL).

I'm just running the changes through a final set of tests, hopefully it will be pushed within 15 minutes.

Great, specially because I tried using a Monitor instead of Mutex and now "rails server" segfaults on JRuby 1.7 :P

--