Hi Dan, You can also use the BoilerPlate firmware with ShimmerConnect ( http://www.shimmer-research.com/r-d/software). This allows the sample rate to be configurable from the host (PC) side. Also BoilerPlate has a much more efficient data packet format than AccelGyro or the other BioMOBIUS apps.
Mike On Thu, May 19, 2011 at 1:33 AM, steve ayer <[email protected]> wrote: > hi dan, > > yes, sure it's possible to go faster; just change the sampling interval > from 5 to 2 milliseconds. you can also consider modifying the packet size > to contain multiple samples and mitigate the rf (and bus) over head by > sending many samples sets in a single packet. > > bear in mind that conventional kinematics measurement practice holds that > most of the data you'll collect at this speed may look like noise... > > i hope that this helps, > > steve > > > On 05/18/2011 03:59 PM, Daniel Kelly wrote: > >> Hi, >> >> Im using a shimmer2r sensor (with an accel and gyro and using the >> accelGyro firmware packaged with the development kit). >> >> At the minute im getting 200Hz, but im wondering if it is possible to >> increase this rate to ~500hz? >> >> Regards, >> Dan >> >> >> >> _______________________________________________ >> Shimmer-users mailing list >> [email protected] >> https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users >> > _______________________________________________ > Shimmer-users mailing list > [email protected] > https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users >
_______________________________________________ Shimmer-users mailing list [email protected] https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users