"The point where I currently disagree with Rob and Randy is on the
granularity of the timer.  Whatever granularity is chosen bounds the
maximum signing rate.  Thus, if you use a 1-second clock, you can't
sign more than 1 object/sec.  (Well, you can cheat and "borrow" from
future seconds, up to the actual clock skew, but that does cut your
margin.)  If we go with a nanosecond timer, we're limited to 10^9
objects/sec, ever.  I'm not convinced we can predict the future well
enough to know that that's reasonable, so I've suggested that the spec
support fractional seconds -- we can always extend the number of
significant digits to the right of the radix point without a protocol
change.

I could live with a 10^9 message/sec limitation (it's not a system global, but per client/server relation)... If that's not enough, the <timestamp seconds>.<sequence-within-the-same-second> tuple solves all issues, I think.

Robert(K)