Thank you very much ,Would you like to tell me how to specify the energy range? 
Best wishes 
Zhendong Guo

At 2010-07-25 23:09:35,"Руслан Жачук" <[email protected]> wrote:
It looks like it is valid LDOS file, but it is empty.
I think you didn't specify energy range correctly for LDOS, so you got empty 
file.
LDOS files are usually big (megabytes).

Regards
Ruslan Zhachuk



2010/7/25 郭振东 <[email protected]>

I have got the File *.LDOS,but I cannot get the STM image.Would you like to 
give me some help?
Thank you very much! I will send my *.LDOS to you!


At 2010-07-23 19:02:31,"Руслан Жачук" <[email protected]> wrote:
WSxM can be freely downloaded from www.nanotec.es
plstm is in Utility folder of siesta package. Compilation is straightforward.

For instructions on how to generate LDOS file look in Siesta manual.

Ruslan


2010/7/23 郭振东 <[email protected]>
Thank you very much! Would you like to give me an example ? 


At 2010-07-23 11:24:38,"Руслан Жачук" <[email protected]> wrote:
First you should produce LDOS file by Siesta. 
Then use WSxM to make constant-current image or plstm to make constant-height 
image.

Regards
Ruslan Zhachuk


2010/7/23 郭振东 <[email protected]>

Hello  everyone
     Would you like to tell me how to get the STM image by siesta ? I will very 
thankful!
   
 Zhendong  Guo
Institute of Microelectronics and Optoelectronics, Room 516, 
Dept. of Information Science & Electronic Engineering 
Zhejiang University




您想拥有和网易免费邮箱一样强大的软件吗?




网易邮箱,没有垃圾邮件的邮箱。




您想拥有和网易免费邮箱一样强大的软件吗?

Responder a