Hi Saikat,

 Assuming your structure is stable, negative frequencies generally
 mean poor convergence of either, the optimized structure or the
 following FC run.

 I have no experience with CNT, though the parameters you're using
 seem pretty ok to me, but for one: it is "Meshcutoff" not "Messcutoff"
 as you type.
 In any case, 150 Ry might be on the low side (depending on box's size).
 It is a particularly critical parameter, check the manual for the
 "eggbox" effect.
 Also, you might want to check the *.FC file that Siesta outputs. Namely,
 the forces for + and - displacements should be about the same,
 particularly on the moving atom (file structure has been explained
 in a recent post to the list).

 Good luck,

 Roberto


On Mon, 15 Oct 2012, [email protected] wrote:

Dear siesta user,

I am doing phonon calculation of carbon nanotube using siesta. But I am
getting negative frequencies for more than half of the calculated
frequencies. I wanted to know reason for getting negative frequencies
of my calculation.


I have optimized the structure using

MD.MaxForceTol          0.001 eV/Ang


And condition for scf are as follows

DM.Tolerance            0.5d-4
DM.Require.Energy.Convergence true
DM.Energy.Tolerance      .5d-4 eV

My input file for type of run- FC  ----



SystemName       Phonon calculation    # Descriptive name of the system
SystemLabel            Phonon_fc           # Short name for naming files

# Output options

LongOutput      false

# Species and atoms
%block ChemicalSpeciesLabel
 1  6  C
%endblock ChemicalSpeciesLabel

NumberOfSpecies        1
WriteKpoints       true


PAO.Basis<basis.fdf

LatticeConstant   1 Ang
Messcutoff         150 Ry
Kgridcutoff        10.0 Ang
xc.functional         GGA
xc.authors            PBE
DM.UseSaveDM           true
MaxSCFIterations       500
DM.MixingWeight      0.25
DM.NumberPulay       4

DM.Tolerance            0.4d-4
DM.Require.Energy.Convergence true
DM.Energy.Tolerance     .5d-4 eV
#Atomic coordinates
%include PhononFC.fdf
AtomicCoordinatesFormat     Fractional

Thanking You.


__________________

Saikat Paik
IIT Kanpur
UP,India

Responder a