Dear Rahman Thank you for your kind reply, I will rerun the calculations with 
your suggestions, and verify the relationship between the parameters defined in 
the ProjectedDensityOfStates block and the DOS results.There is another 
question puzzled me these days. I get the band structure of the (primitive) 
unit cell (actually is LiF), and the unit of high-symmetry points defined in 
the Bandlines block is given by ReciprocalLatticeVectors option. When I am 
trying to do the same calculation with a supercell, can I use the previous 
Bandlines block (not changed) in the new supercell calculations. Because I 
think in the supercell calculations, the LatticeVectors is expanded several 
times, maybe I should find the new locations of the X, W, K and Gamma points 
inside the new BZ.RegardsFei Mao
USC

在2015-08-12,Gul Rahman <[email protected]> 写道:-----原始邮件-----
发件人: Gul Rahman <[email protected]>
发送时间: 2015年8月12日 星期三
收件人: "[email protected]" <[email protected]>
主题: Re: [SIESTA-L] The problem of DOS and PDOS calculation

Dear Fei,
Good that you have solved your problem.
Well, the peak width (an energy) is for broadening the eigenvalues. You can 
choose any number and plot the DOS to see how it looks like. It is for 
broadening, so it will affect the shape of your DOS. You can play with it and 
plot your DOS for different values of broadening for the same k-points.

The number of points are just the number (number of points in the energy 
window) to connect two points in numerical integration. In the language of 
numerical methods, if you use large number of points then your function (in 
this case your DOS) will be like a curve, and if you use very small number then 
it will look like a line. We do the same when we plot the band structure. You 
can also play with it.
Regards,
Gul

 
Dr. Gul Rahman
Assistant Professor,
Department of Physics,
Quaid-i-Azam University,
Islamabad, Pakistan
http://www.qau.edu.pk/profile.php?id=818020






On Tuesday, 11 August 2015, 7:16, 毛飞 <[email protected]> wrote:



>Dear Rahman
 
Thank you for you kind reply, and your suggestion works!
 
Can you explain to me why, is there any relationship or requirement for 
choosing the peak width and the number of points in the energy window in the 
block definition.
 
Regards
Fei

在2015-08-11,Gul Rahman <[email protected]> 写道:-----原始邮件-----
发件人: Gul Rahman <[email protected]>
发送时间: 2015年8月11日 星期二
收件人: "[email protected]" <[email protected]>
主题: Re: [SIESTA-L] The problem of DOS and PDOS calculation

Try something like this
%block ProjectedDensityOfStates
  -25.00  20.00  0.100  1500  eV
%endblock ProjectedDensityOfStates



 
Dr. Gul Rahman
Assistant Professor,
Department of Physics,
Quaid-i-Azam University,
Islamabad, Pakistan
http://www.qau.edu.pk/profile.php?id=818020






On Monday, 10 August 2015, 18:38, 毛飞 <[email protected]> wrote:



Dear Siesta Developers and Users I am trying to calculate DOS and PDOS. To 
calculate both I add a block label in the input file, such us:%block 
ProjectedDensityOfSTates -10.0   10.0   0.05  700 eV%endblock 
ProjectedDensityOfStatesI obtain two output files SystemLabel.DOS and 
SystemLabel.PDOS. However, the *.DOS is totally empty, and the content in the 
*.PDOS is, 
<pdos>
<nspin>1</nspin>
<norbitals>  18</norbitals>
<energy_values units="eV">
</energy_values>
 
It is strange, I cannot understand these results, and I have searched the mail 
archive of Siesta, but I don’t find the explanations to this problem. Dose 
anybody encounter the problem before? I am using the version of siesta-3.2-pl-5.
 
Regards
Fei Mao
USC


























Responder a