Dear Transiesta users, I found the source of the error in my calculations. It was related to the wrong description of semi-inf-direction in the TranSIESTA input file. The electrodes were extended in a3-direction and by mistake I enter the a1 as the semi-inf part.
Regrades, Azar On Thu, Apr 6, 2017 at 3:37 AM, azar ostovan <[email protected]> wrote: > Dear Transiesta users, > > I am trying to run a transport calculation using TranSIESTA code but I got > the following error each time: > > nrows_g=768 nrows=768 sparsity=.9580 nnzs=565056, refcount: 3> > Electrode elec-x has no transfer matrix. > The self-energy cannot be calculated with a zero transfer matrix! > Electrode elec-x has no transfer matrix. > > could you please tell me what is wrong in my electrode calculation? > > > > All the best, > Azar >